摘要
锰铜、圆钢及石墨复合接地材料作为输电线路杆塔接地网常见的三种接地材料,因材料本身电磁参数的不同使得接地体工频与冲击散流特性有区别。为此针对三种典型接地材料,采用软件CDEGS对3种接地体进行仿真建模计算,分别对比分析了3种常见金属及非金属接地材料在不同频率、不同土壤条件及不同直径下的接地散流特性,阐述了接地体散流特性对接地阻抗的影响并给出结论,研究结果为输电线路杆塔接地网选材及外延降阻设计提供参考依据。
Copper,steel and graphite composite grounding material are three commonly used grounding materials in transmission tower grounding grid.There are differences of power frequency and impulse current release characteristics among the above three grounding material owing to their different electromagnetic characteristics.Simulation calculations have been conducted on their grounding current release characteristics by CDEGS.Three factors have been considered in this paper,including different frequencies,different soil condition and different diameter.The effect of current release characteristics on grounding resistance have been analyzed in detail.The work conducted in this paper can provide reference for the selection of grounding material and expand designation of grounding resistance reduction.
出处
《水电能源科学》
北大核心
2016年第9期178-182,共5页
Water Resources and Power
关键词
接地材料
石墨复合接地材料
有效散流长度
散流特性
grounding material
graphite composite electrical grounding material
effective length of current release
current release characteristics