摘要 In order to investigate the mechanism of the temperature oscillation in loop heat pipes,this paper investigated the movement of the phase interface as the changed input power by a mass-spring-damper model.The model was solved with MATLAB and was used to explain the high-frequency and low-amplitude temperature oscillation.Temperature variation with the input power from 20 W to 75 W was investigated based on a LHP prototype in a literature.The model agreed well with the experimental data in the literature.The simulation results suggested that the movement of the liquid column was caused by the fluctuation of pressure difference applied on the liquid column and the stiffness coefficients of the vapor springs increasing with the input power.According to parameter analyses,the temperature oscillation at the outlet of the condenser can be weakened by increasing the mass of the liquid column and keeping the temperature at the outlet of the condenser steady. In order to investigate the mechanism of the temperature oscillation in loop heat pipes, this paper investigated the movement of the phase interface as the changed input power by a mass-spring-damper model. The model was solved with MATLAB and was used to explain the high-frequency and low-amplitude temperature oscillation. Temperature variation with the input power from 20 W to 75 W was investigated based on a LHP prototype in a literature. The model agreed well with the experimental data in the literature. The simulation results suggested that the movement of the liquid column was caused by the fluctuation of pressure difference applied on the liquid column and the stiffness coefficients of the vapor springs increasing with the input power. According to parameter analyses, the temperature oscillation at the outlet of the condenser can be weakened by increasing the mass of the liquid column and keeping the temperature at the outlet of the condenser steady.
出处 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2016年第5期82-89,共8页 哈尔滨工业大学学报(英文版)
基金 Sponsored by the National Natural Science Foundation of China(Grant No.51276012)
关键词 loop heat pipe temperature oscillation DISPLACEMENT mass-spring-damper model steady state parameters loop heat pipe temperature oscillation displacement mass-spring-da^nper model steady state para^neters
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部