期刊文献+

无传感器无刷直流电机重投冲击研究与抑制

Research and Suppression of Reclosing Impact for Brushless DC Motor Without Position Sensors
下载PDF
导出
摘要 断电重投问题常见于无位置传感器无刷直流电机运行过程中,重投时强烈的电流与转矩冲击极易造成电机失步,甚至损坏电机与控制器。从冲击产生的原理出发,针对无位置传感器无刷直流电机的断电重投过程,从瞬态与稳态两个角度进行了分析。推导出了冲击电流的表达式,并提出了抑制冲击的方法。因此以滑模观测器为基础,设计了无位置传感器无刷直流电机寻优重投控制系统。最后,通过仿真验证,证明了该控制系统在抑制断电重投冲击方面的有效性。 Reclosing Process is pervasive in sensodess brushless DC motor drives, which can result in strong current and torque impacts to motors and their controllers. Generation principle of impacts to sensorless brushless DC motor was analyzed under transient and steady states. Expressions of impact current were derived, at the same time, a method of impact reduction was also proposed. Based on sliding mode observer, an optimization reclosing control system of sensorless brushless DC motor was designed. Simulation results demonstrate that the proposed control system is effective in the reduction of reclosing impacts to sensorless brushless DC motors.
出处 《微电机》 2016年第9期41-46,共6页 Micromotors
关键词 无刷直流电机 断电重投 无位置传感器 滑模观测器 brushless DC motor power reclosing sensorless sliding mode observer
  • 相关文献

参考文献10

  • 1Dangherty R H. Analysis of Transient Electrical Torque and Shaft Torques in Induction Motors as a Result of Power Supply Disturb- ances [ J ]. IEEE Transactions on Power Apparatus and Systems, 1982, 101(8) : 2826-2836.
  • 2A Stirban, I Boldea, F Blaabjerg. FEM Assisted Position and Speed Observer for BLDC PM Motor Drive Sensorless Control, with Experiments [ C]. IEEE 2010 Proc. 14th International Power Elec- tronics and Motion Control Conference, 2010: 34-40.
  • 3J Falz, M haneei, A Keyhani. Performance Analysis of Fast Relos- ing Transients in Induction Motors [ J]. IEEE Transactions on Ener- gy Conversion, 1999, 14(1 ) : 101-107.
  • 4. Htsui J C S. Magnitude, Amplitudes and Frequencies of Induction Motor Air-gap Transient Torque Through Simultaneous Reclosing with or Without Capacitors [ J]. IEEE Transactions on Power Apparatus and Systems, 1985, 104(6): 1519-1526.
  • 5耿艳杰,冯志华.异步电机在重投入中过渡过程的建模和仿真[J].防爆电机,2005,40(4):20-22. 被引量:10
  • 6高吉增,杨玉磊,崔学深.感应电动机失电残压的研究及其对重合过程的影响[J].电力系统保护与控制,2009,37(4):45-48. 被引量:43
  • 7汤晓燕.三相感应电动机瞬间断电重新投入电网时的瞬态[J].电机与控制学报,2001,5(2):98-102. 被引量:31
  • 8J C Das. Effects of Momentary Voltage Dips on the Operation of In- duction and Synchronous Motors [J]. IEEE Transactions on Indus- try Applications, 1990, 26(4) : 711-718.
  • 9A Wang, Z Ling, W Liu. Residual Voltages Analysis in Reclosing Process for Induction Machine [J]. IEEE 2008 Proc. 7th World Congress on Intelligent Control and Automation, 2008 : 4785-4788.
  • 10高雅,刘卫国,骆光照.大惯量负载永磁同步电机断电-寻优重投控制系统[J].电工技术学报,2014,29(5):62-69. 被引量:9