摘要 中国改进型三环路压水堆(CPR1000)核电厂循环水系统设置了泵、电机、齿轮箱的轴承温度、润滑油压力、电机泄漏探测等的单测点跳泵逻辑,这些单点跳泵信号增加了误跳循环水泵的风险,严重影响了机组的稳定运行。推荐了5种可行的跳泵保护改造方案,并对各类改造方案进行了优缺点分析研究,电厂可根据保护信号的实际设置情况选择合适的跳泵保护方案,以减少保护误动作,提高机组可用率和经济性。 Single measuring point tripping pump logic was set in the pump, motor, gear box temperature, lubricating oil pressure and motor leakage detection in China improved three loop PWR(CPR1000)nuclear power plant circulating water system. These single tripping signals increased the risk of error tripping in circulating water pump, which seriously affected the stable operation of the unit. Five feasible kinds of tripping pump protection reform schemes were recommended, and the advantages and disadvantages were analyzed and studied. According to the actual setting of protection signal, appropriate pump protection scheme could be chose by the power plant, improving the availability and economical efficiency of the unit.
作者 吉天生
出处 《能源研究与管理》 2016年第3期77-79,91,共4页 Energy Research and Management
关键词 中国改进型三环路压水堆(CPR1000) 循环水泵 控制逻辑 单点跳泵 CPR1000 circulating water pump control logic single-point tripping pump
  • 相关文献

参考文献4

  • 1王魁汉.温度测量实用技术[M].北京:机械工业出版社,2006.
  • 2电力行业核电标准化技术委员会.核电厂常规岛仪表与控制系统设计规程:DL/T5423-2009[S].北京:中国电力出版社,2009.
  • 3中华人民共和国国家能源局.火力发电厂热工保护系统设计技术规定:DL/T5428-2009[S].北京:中国电力出版社,2009.
  • 4李慧婷,洪海波.热工保护误动及拒动的原因和应对策略[J].内蒙古石油化工,2013,39(22):66-67. 被引量:4

二级参考文献4

  • 1魏春岭.Ovation DCS在托克托电厂的设计应用[J].世界仪表与自动化,2004,8(12):29-32. 被引量:2
  • 2徐科军.传感器与检测技术[M]{H}北京:电子工业出版社,2007.
  • 3陈守仁.自动检测技术及仪表[M]{H}北京:机械工业出版社,1989.
  • 4孙奎明;时海.600MW级火力发电机组丛书-热工自动化(第二版)[M]{H}北京:中国电力出版社,2009.

共引文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部