期刊文献+

Evaluation of anterior and posterior surfaces of the cornea using a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments 被引量:3

Evaluation of anterior and posterior surfaces of the cornea using a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments
下载PDF
导出
摘要 AIM:To evaluate corneal parameters measured with a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments(ICRS).METHODS:Fifty eyes of 40 keratoconus patients had Ferrara ICRS implantation from November 2010 to April2014.Uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),refraction,keratometry,asphericity,elevation,pachymetry,root mean square(RMS),spherical aberration and coma were studied.All patients were evaluated using a dual Scheimpflug system.RESULTS:The mean follow-up time after the procedure was 12.7mo.The mean UCVA improved from0.82 to 0.31(P〈0.001);the mean BCVA improved from0.42 to 0.05(P〈0.0001),the mean spherical refraction changed from-3.06 ±3.80 D to-0.80 ±2.5 D(P〈0.0001)and the mean refraction astigmatism reduced from-4.51 ±2.08 D to-2.26±1.18 D(P〈0.0001).The changes from preoperative to postoperative,in parameters of the anterior and posterior surface of the cornea,were statistically significant except the elevation posterior at the apex of the cornea and posterior asphericity.CONCLUSION:The implantation of Ferrara ICRS induces changes in both anterior and posterior surfaces of the cornea. AIM:To evaluate corneal parameters measured with a dual Scheimpflug analyzer in keratoconus patients implanted with intrastromal corneal ring segments(ICRS).METHODS:Fifty eyes of 40 keratoconus patients had Ferrara ICRS implantation from November 2010 to April2014.Uncorrected visual acuity(UCVA),best corrected visual acuity(BCVA),refraction,keratometry,asphericity,elevation,pachymetry,root mean square(RMS),spherical aberration and coma were studied.All patients were evaluated using a dual Scheimpflug system.RESULTS:The mean follow-up time after the procedure was 12.7mo.The mean UCVA improved from0.82 to 0.31(P〈0.001);the mean BCVA improved from0.42 to 0.05(P〈0.0001),the mean spherical refraction changed from-3.06 ±3.80 D to-0.80 ±2.5 D(P〈0.0001)and the mean refraction astigmatism reduced from-4.51 ±2.08 D to-2.26±1.18 D(P〈0.0001).The changes from preoperative to postoperative,in parameters of the anterior and posterior surface of the cornea,were statistically significant except the elevation posterior at the apex of the cornea and posterior asphericity.CONCLUSION:The implantation of Ferrara ICRS induces changes in both anterior and posterior surfaces of the cornea.
出处 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第9期1283-1288,共6页 国际眼科杂志(英文版)
关键词 KERATOCONUS intrastromal comeal ringsegments dual Scheimpflug keratoconus intrastromal comeal ringsegments dual Scheimpflug
  • 相关文献

同被引文献7

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部