期刊文献+

一种基于绿光的可穿戴式光电容积脉搏波测量系统 被引量:12

A wearable photoplethysmography measurement system based on green light
下载PDF
导出
摘要 脉搏波中蕴含丰富的血流动力学信息。利用无创的方法检测脉搏波并推导出人体心血管系统生理、病理特征成为研究的热点。设计一套可穿戴式的脉搏波提取设备,该设备包括MCU控制模块、信号采集模块、蓝牙模块、电源模块。分析光电容积法获取脉搏波的原理,采用523 nm绿光和环境光学传感器作为设备核心,详解描述了硬件开发模型,给出了信号处理部分的关键代码。实验结果表明,所设计的脉搏波提取设备在手腕、手指和额头等部位,能够很好地描绘脉搏波,具有很强的应用性。 The pulse wave contains rich hemodynamic information. The non-invasive method used to detect the pulse wave and deduce the physiological and pathological features of human cardiovascular system becomes the research hotspot. A set of wearable pulse wave extraction device was designed, which includes MCU control module, signal acquisition module, power supply module, and Bluetooth module. The principle of photoplethysmography (PPG) to acquire the pulse wave is analyzed. The luminous diode at 523 nm and environmental optical sensor are taken as the core of the device. The hardware development mod- el is described in detail, and the key codes of signal processing are given. The experiment results indicate that the designed pulse wave extraction device can describe the pulse wave of wrists, fingers and forehead, and has good applicability.
出处 《现代电子技术》 北大核心 2016年第20期125-128,共4页 Modern Electronics Technique
基金 国家科技支撑计划课题资助(2013BAH14F01) 国家自然科学基金资助(61301059)
关键词 脉搏波提取 无创检测方法 光电容积脉搏波 信号处理 pulse wave extraction non-invasive detection method phot0plethysmography signal processing
  • 相关文献

参考文献10

二级参考文献66

  • 1徐玲,苑晓红,丁迎晓.影响脉搏血氧饱和度结果的原因分析及护理干预[J].齐鲁护理杂志,2006,12(02A):218-218. 被引量:11
  • 2Edmund H Suckow.便携式医疗电子设备的设计考虑[J].电子与电脑,2007(1):30-31. 被引量:1
  • 3张福学.传感器敏感元件实用指南[M].北京:电子工业出版社,2003.
  • 4Keisuke Matsushita,Kazuo Aoki. Fundamental study of re- flection pulse oximetry[J]. Optical Review, 2003,10 (5) : 482.
  • 5Nilsson L, Johansson A, Kalman S. Respiration can be monitored by photoplethysmography with high sensitivityand specificity regardless of anaesthesia and ventilatory mode[J]. Acta Anaesthesiologica Scandinavica, 2005,49 (8) :1157-1162.
  • 6Nilsson L, Goscinski T, Johansson A, et al. Age and gen- der do not influence the ability to detect respiration by photoplethysmography[J]. Journal of Clinical Monitoring and Computing,2006,20(6) :431-436.
  • 7Clifton D, Douglas J G, Addison P S, et al. Measurement of respiratory rate from the photoplethysmogram in chest clinic patients[J]. Journal of Clinical Monitoring and Com- puting, 2007,21 ( 1 ) : 55-61.
  • 8Lin Yue-Der, Liu Wei-Ting, Tsai Ching-Ohe, et al. Coher- ence analysis between respiration and PPG signal by bi- variate AR model[J]. Engineering and Technology, 2009, 53:847-852.
  • 9Fleming S G,Tarassenko L. A comparison of signal pro- cessing techniques for the extraction of breathing rate from the photoplethysmogram[J]. International Journal of Biomedical Sciences, 2007,2(4) : 232-236.
  • 10Samuele Del Bianco, Fabrizio Martel, Giovanni Zaccanti. Penetration depth of light re-emitted by a diffusive medi- um: theoretical and expetimental investigation [J]. Phy. Med. Biol., 2002,47 : 4131-4144.