摘要
针对非隔离型三相三桥臂光伏逆变器无法有效抑制漏电流的问题,提出基于三相四桥臂拓扑的漏电流解决方案。建立非隔离型三相四桥臂光伏逆变器系统共模模型,分析了影响系统漏电流的主要因素和变量,提出一种基于布尔函数逻辑运算的新型载波调制策略。该调制可以实现共模电压恒定,从而有效抑制漏电流。最后搭建了TMS320F28335DSP+XC3S400FPGA数字控制硬件实验平台,对提出的新型载波调制进行了实验研究,并与传统调制方案进行了对比分析,实验结果验证了提出方案的有效性。
In order to solve the problem of the leakage current in three-phase photovoltaic (PV) inverter systems, a new solution of the leakage current reduction is proposed with the three-phase four-leg PV inverter. The common mode loop model of the transformerless four-leg PV inverter is presented. The effect of different factors and variables on the leakage current is discussed. A new modulation strategy based on Boolean logic function is then proposed to ensure the constant common-mode voltage. And thus the leakage current can be significantly suppressed. Finally the proposed modulation is implemented on the TMS320F28335DSP + XC3S4OOFPGA digital control hardware platform. And the performance is also presented by comparison with the conventional modulation methods. The experiment results verifv the effectiveness of the nronosed modulation strategy.
出处
《电工技术学报》
EI
CSCD
北大核心
2016年第19期66-73,共8页
Transactions of China Electrotechnical Society
基金
国家自然科学基金(51307149)
河北省杰出青年基金(2016203133)
中国博士后基金(2015T80230)资助项目
关键词
非隔离型光伏系统
三相四桥臂逆变器
脉冲宽度调制
漏电流
Transformerless photovoltaic system, three-phase four-leg inverter, pulse width modulation,leakage current