期刊文献+

一种新型Co^(2+)荧光探针的合成及其性能研究 被引量:5

Synthesis and Performance of Novel Fluorescent Probe for Co^(2+)
下载PDF
导出
摘要 以8-羟基喹啉衍生物与2,4-二羟基苯甲醛为原料,合成了一种新型的离子荧光探针HQHD。该化合物结构通过红外、氢谱、碳谱以及高分辨质谱进行确认。当以V(乙腈)∶V(水)=1∶9缓冲溶液为溶剂时,荧光探针的性能研究表明,在16种常见金属离子和NH^+_4中,HQHD对Co^(2+)具有较好的专一识别能力,p H在6.98~8.6范围内对Co^(2+)的识别能力最强。当Co^(2+)与其他离子形成共存离子溶液时,并不影响HQHD对Co^(2+)的检测效果,说明配体HQHD具有较强的抗干扰能力。当Co^(2+)在0.5×10^(-5)~5×10^(-5)mol/L的浓度范围内,体系的荧光强度ΔF与Co^(2+)的浓度呈现良好的线性关系,线性拟合系数为0.982 6,检测限为9.77×10^(-8)mol/L。Job's plot曲线表明,Co^(2+)与配体比为1∶1。 A novel Co2+ fluorescent probe benzildihydrazone derivatives HQHD was synthesized via 8-hydroxyquinoline and 2,4- dihydroxybenzaldehyde as raw materials. The structures of compounds were confirmed by IR,1HNMR , 13 CNMR , HRMS. When in acetonitrile: water = 1 : 9 buffer solution(pH 7.15) ,the performance of the fluorescent probe showed that HQHD had good recog- nition ability for Co2+ between 16 kinds of general metal ions and NH4+ . The ability to recognized the Co2+ is strongest when pH is 6. 98- 8.6. When Co2+ coexistence with other ions, it did not affect HQHD detection effect of Co2+ , show that the ligand HQHD has strong anti-interference ability,when the concentration range of Co2+ was 0.5 × 10 -5 -5 × 10-Smol/L,fluorescence intensity of AF with the concentration of Co2+presented a good linear relation,linear fitting coefficient is 0. 982 6, detection limit of 9.77 ×10-5 mol/L. Job's plot showed that ratio of Co2+ with ligand was 1: 1.
出处 《化学试剂》 CAS 北大核心 2016年第10期995-998,共4页 Chemical Reagents
基金 国家自然科学基金资助项目(31270577) 徐州工程学院青年教师科研专项基金项目(XKY2012305)
关键词 合成 Co2+ 荧光探针 专一识别 强抗干扰能力 Co2+, synthesis Co fluorescent probe special identification strong anti-interference ability
  • 相关文献

参考文献12

  • 1MAIGA A, DLALLO D, BYE R, et al. Determination of some toxic and essential metal ions in medicinal and edi- ble plants from Mali [J]. J. Agric. Food Chem. , 2005,53 (6) :2 316-2 321.
  • 2SELDEN A I,NORBERG C,KARLSONSTIBER C,et al. Cobalt release from glazed earth enware:observations in acase of lead poisoning[J]. Environ. Toxicol. Pharmacol 2007,23(10) :129-131.
  • 3YEYNG H Y A, NEW E J, CHANG C J. A selective reac- tion-based fluorescent probe for detecting cobalt in living cells [J]. Chem. Commun. , 2012,48 ( 43 ) : 5 268-5 270.
  • 4BEBE F A A,ERIBAL C S,RAMAKRISHNA G,et al. A ~ turn-on " fluorescensensor for the selective detection of cobalt and nickel ions in aqueous media[J]. Tetrahedron Lett. ,2011,43(52):5 554-5 558.
  • 5GHAEDI M,AHMADI F,SHORKROLLAHI A. Simulta- neous preconcentration and determination of copper,nick- el,cobalt and lead ions content by flame atomic absorp- tion spectrometry [J]. J. Hazard. Mater. , 2007,142 ( 1/ 2 ) : 272-278.
  • 6RAO K S, BALAJI T, RAO T P, et al. Determination of iron, cobalt, nickel, manganese, zinc, copper, cadmium and lead in human hair by inductively coupled plasma-a- tomic emission spectrometry [J]. Speetrochim. Acta B, 2002,8(57) :1 333-1 338.
  • 7MASHRAQUI S H,CHANDIRAMAMI M,BETKAR R,et al. A simple internal charge transfer probe offering dual optical detection of Co ( Ⅱ ) via color and fluorescence modulations [J]. Tetrahedron Lett. , 2010,9 ( 51 ) : 1 306- 1 308.
  • 8TSOUTSI D, GUERRINI L, HERMIDA J M, et al. A1- varez-puebla R A,simuhaneous SERS detection of copper and cobalt atultratrace levels [J]. Nanoscale, 2013, 5 (13) :5 841-5 846.
  • 9GAO Zhi-qiang, WANG Guang-qing, LI Pei-biao, et al. Differential pulse vohammetric determination of cobalt with a perfluorinated ulfonated polymer-2, 2-bipyridyl modified carbon paste electrode [J]. Anal. Chem. , 1991, 63(10) :953-957.
  • 10LI Xiao-hua, GAO Xing-hui, MA Hui-min. Design state- gies for water-soluble small molecular chromogenic and fluorogenic probers [J]. Chem. Rev. , 2014, 114 ( 1 ) : 590-659.

二级参考文献2

共引文献1

同被引文献12

引证文献5

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部