一种用于电阻抗断层成像图像后处理的“像素化”自适应剖分方法

Pixelized adaptive mesh method for postprocessing of electrical impedance tomography images
下载PDF
导出
摘要 目的:研究一种便于电阻抗断层成像(electrical impedance tomography,EIT)图像后处理的方法。方法:从算法角度入手,对现有剖分方法进行改造,选择相同直角三角单元作为基本的剖分单元,每2个直角三角单元组成一个方格,作为一个像素点。基于患者CT图提取颅脑轮廓,作为剖分边界。然后使用"像素化"剖分方法对提取出的轮廓进行自适应剖分,生成剖分模型后利用阻尼最小二乘算法完成重建,以此获取"像素化"的重建图像。结果:使用"像素化"自适应剖分方法,可以在不引入过大误差的情况下,获取与位图类似的"像素化"重建图像。"像素化"重建图像单元邻域关系明确,不用经过转换,可直接套用针对位图的图像处理算法。结论:"像素化"自适应剖分方法可以有效地简化EIT图像后处理过程,为电阻抗图像分析、指标提取奠定基础。 Objective To propose a pixelized adaptive mesh method for the postprocessing of electrical impedance tomography(EIT) images.Methods The algorithm of the existing mesh method was modified.The right triangle was used as the basic meth unit,and two triangles formed a square as a pixel.Craniocerebral contour was extracted from CT image to determine mesh boundary.Then adaptive mesh was carried out with pixelized method to generate a mesh model,and damped least square method was used for reconstruction to acquire pixelized reconstructed images.Results The proposed method resulted in pixelized reconstructed images similar to bitmap with no great errors introduced.The pixelized image units gained clear relationships between the neighboring ones,and image processing algorithms for the bitmap could be applied directly without any transformation.Conclusion The pixelized adaptive method simplifies the postprocessing of EIT images,and lays a foundation for EIT image analysis and index extraction.
出处 《医疗卫生装备》 CAS 2016年第9期1-4,共4页 Chinese Medical Equipment Journal
基金 国家自然科学基金项目(51207161) 国家科技支撑计划课题(2011BAI08B13 2012BAI20B02) 军队面上课题(CWS12J102)
关键词 电阻抗断层成像 像素化 图像处理 EIT pixelization image processing
  • 相关文献

参考文献13

  • 1徐灿华,董秀珍.生物电阻抗断层成像技术及其临床研究进展[J].高电压技术,2014,40(12):3738-3745. 被引量:40
  • 2BROWN B H,BARBER D C,SEAGAR A D. Applied poten- tial tomography:possible clinical applications[J]. Clin Phys Physiol Meas, 1985,6(2 ) : 109-121.
  • 3KIM B S,KIM K Y,KIM S. Image reconstruction using adaptive mesh refinement based onadaptive thresholding in electrical impedance tomography[J]. Nuclear Engineering and Design, 2013,270: 421-4.26.
  • 4邓娟,王妍,吕婧华,任超世.三种EIT算法重建图像评价的仿真研究[J].医疗卫生装备,2010,31(5):1-3. 被引量:10
  • 5BAGSHAW A P,LISTON A D,BAYFORD R H,et td. Electri- cal impedance tomography of human brain funelion using re- construction algorithms based on the finite element method[J]. Neuroimage, 2003,20(2 ) : 752-764.
  • 6MURAl T, KAGAWA Y. Eleetrieal impedance computed to- mography based on a finite element model[J]. IEEE Trans Biomed Eng, 1985,32( 3 ) : 177-184.
  • 7杨滨.引人人脑颅骨电阻率非均匀分布的电阻抗断层成像算法研究[D].西安:第四军医大学,2013.
  • 8梁乐,徐灿华,沈志鹏,代萌,杨滨,付峰,董秀珍.用于生物电磁场分析的脑部三层有限元模型构建[J].医疗卫生装备,2014,35(9):12-14. 被引量:6
  • 9JAVAHERIAN A,MOVAFEGHI A,FAGHIHI R,et td. An exhaustive criterion for estimating quality of images in elec- trical impedance tomography with application to clinical imaging[J]. Journal of Visual Communication and Image Representation, 2013,24( 7 ) : 773-785.
  • 10冈萨雷斯.数字图像处理[M].3版.北京:电子工业出版社,2011.

二级参考文献30

  • 1任超世.EIT──一种诱人的医学成像新技术[J].电子科技导报,1996(5):9-13. 被引量:10
  • 2任超世,王妍.阻抗成像实用化应用技术研究[J].中国医学装备,2007,4(5):1-5. 被引量:8
  • 3邓娟,王妍,任超世.EIT图像重建算法的进展研究[J].中国医学装备,2007,4(6):1-5. 被引量:5
  • 4WANG Zhou,BOVIK A C.A universal image quality index[J].IEEE Signal Processing Letters,2002.9(3):81-84.
  • 5Avis N J,Barber D C,Brown B H,et al.Back-projections in applied potential tomography images due to non-uniform reference conductivity[J].Clin Phys Physiol Meas,1992,13(Suppl A):113-117.
  • 6Tadakuni Murai,Yukio Kagawa.Electric impedance computed tomography based on a finite element model[J].IEEE Trans Biomed Eng,1985,34:177-184.
  • 7Yonkey T J,Webster J G,Tompkins W J.Comparing Reconstruction Algorithms for Electrical Impedance Tomography[J].IEEE TransBiomed Eng,1987,34:843-852.
  • 8Yang W Q,Spink D M,York T A,et al.An image reconstruction algorithm based on Landweber iteration method for electrical capacitance tomography[J].Meas Sci Technol,1999,10:1 065-1 069.
  • 9Tikhonov A N,Arsenin V Y.Solutions of Ⅲ-Posed Problems[M].New York:Wiley,1977.
  • 10WANG Yan,SHA Hong,ZHAO Shu,et al.Influences of Compound Electrode Parameter on Measurement Sensitivity and Reconstruction Quality in Electrical Impedance Tomography[C] //Proceedings of World Congress on Medical Physics and Biomedical Engineering,Seonl,Korea.Berlin:Springer c,2006:3433-3 436.

共引文献78

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部