通过对吉林某电厂2#炉电除尘器的电控系统用高频电源改造高压电源,分析对比改造前后的电除尘电耗数据及脱硫入口浊度数据,探讨高频电源节能管理在电除尘应用上的可行性。
On the base of the transform about unit 2 ESP of one power plant in Jilin province, from the high frequency power supply to high voltage power supply, and by analyzing and contrasting the before-and-after changes on the data of the energy consumption and the opacity of the entrance of ESP, we can explore the feasibility of improving efficiency and saving energy for high frequency power supply through energy management software.
作者
彭宇泉
PENG Yuquan(Fujian Longking Co., Ltd., Longyan 364000, Chin)
出处
《再生资源与循环经济》
2016年第9期42-44,共3页
Recyclable Resources and Circular Economy
关键词
高频电源
电除尘
改造
节能
high frequency power supply
ESP
alteration
energy-saving