动态血糖监测的准确性与临床应用 被引量:7

The accuracy and clinical application of dynamic blood glucose monitoring
原文传递
导出
摘要 动态血糖监测(CGM)是近年应用于临床的新型血糖监测技术,包括回顾式动态血糖监测和实时动态血糖监测。CGM可以提供连续、全面、可靠的全天血糖信息,了解血糖波动的趋势,并可发现不易被传统监测方法所探测的高血糖和低血糖,因此这种能持续、动态地检测血糖变化的技术是传统血糖监测方法的有效补充。掌握CGM技术的准确性、临床应用特点及适应证,对临床医生至关重要。 Continuous glucose monitoring (CGM) is a new type of blood glucose monitoring technology used in recent years, including the review glucose monitoring and real-time glucose monitoring. CGM can provide continuous, comprehensive and reliable information of blood glucose all day long, can help us to understand the trend of blood glucose fluctuation and to find hyperglycemia and hypoglycemia which are not easy to be detected by traditional monitoring me/hods. So this technology which can detect/he change of glucose continuously and dynamic is the effective supplement to the traditional blood glucose monitoring. To master the accuracy, clinical characteristics and indications of CGM technology is very important for doctors.
作者 李强 郭琳
出处 《中国实用内科杂志》 CAS CSCD 北大核心 2016年第10期833-837,共5页 Chinese Journal of Practical Internal Medicine
关键词 动态血糖监测 实时动态血糖监测 回顾式动态血糖监测 continuous glucose monitoring CGMS RT-CGMS
  • 相关文献

参考文献22

  • 1Mahmoudi Z, Johansen MD, Nergaard HH, et al. Effect of continuousglucose monitoring accuracy on clinicians' retrospective decisionmaking in diabetes: a pilot study[J]. J Diabetes Sci Technol, 2015;9(5): 1092-1102.
  • 2Patton SR; Clements MA. Psychological reactions associated withcontinuous glucose monitoring in youth[J].J Diabetes Sci Technol;2016,10(3):656-661.
  • 3Gai M, Merlo I, Dellepiane S,et al. Glycemic pattern in diabetic patientson hemodialysis: continuous glucose monitoring (CGM) analysis [J],Blood Purif, 2014,38(1): 68-73.
  • 4李强,李鹏杰.血糖波动的意义及临床评估方法[J].中国实用内科杂志,2009,29(9):876-878. 被引量:52
  • 5Tao M, Zhou J, Zhu J; et al. Continuous glucose monitoring revealsabnormal features of postprandial glycemic excursions in women withpolycystic ovarian syndrome[J]. Postgrad Med, 2011, 123(2): 185-190.
  • 6李强,王莹莹,于萍,高萍,邬艳慧,崔璨,王薇,陈莉丽,乔虹,王丽宏,项莹,张众,张巾超.实时动态血糖监测与静脉血糖、毛细血管血糖检测的相关性[J].中华医学杂志,2010,90(42):2971-2975. 被引量:25
  • 7王莹莹,李强,于萍,高萍,邬艳慧,崔璨,王薇,陈莉丽,乔虹,王丽宏,项莹,张众,张巾超.实时动态血糖监测系统在不同时段检测的准确性变化特征及其与血糖波动的关系[J].中华内分泌代谢杂志,2011,27(3):224-228. 被引量:14
  • 8李强.专家点评:工欲善其事必先利其器[J].中华糖尿病杂志,2012,4(9):528-528. 被引量:1
  • 9Andelin M, Kropff J, Matuleviciene V, et al. Assessing the accuracy ofcontinuous glucose monitoring (cgm) calibrated with capillary valuesusing capillary or venous glucose levels as a reference[J].J Diabetes SciTechnol, 2016,10(4): 876-884.
  • 10Chase HP, Kim LM, Owen SL, et al. Continuous subcutaneous glucosemonitoring in children with type 1 diabetes[J]_ Pediatrics, 2001,107(2):222-226.

二级参考文献37

  • 1周健,贾伟平,喻明,马晓静,包玉倩,陆蔚.上海地区中国人餐后血糖状态的特征[J].中华医学杂志,2006,86(14):970-975. 被引量:71
  • 2周健,喻明,贾伟平,李青,李鸣,马晓静,陆蔚,项坤三.应用动态血糖监测系统评估2型糖尿病患者日内及日间血糖波动幅度[J].中华内分泌代谢杂志,2006,22(3):286-288. 被引量:177
  • 3Hirsch IB. Glycemic variability: it's not just about A1C anymore [ J ]. Diabetes Technol Ther,2005 ;7(5 ) :780 - 753.
  • 4Lachin JM, Genuth S, Nathan DM, et al. Effect of glycemic exposure on the risk of microvascular complications in the diabetes control and complications trial-revisited[J]. Diabetes, 2008 ; 57 ( 4 ) : 995 - 1001.
  • 5Derr R,Garrett E,Stacy GA,et al. Is HbA(1c) affected by glycemic instability? [ J ]. Diabetes Care,2003,26 ( 10 ) :2728 - 2733.
  • 6McCarter RJ, Hempe JM, Chalew SA. Mean blood glucose and biological variation have greater influence on HbAI c levels than glucose instability:an analysis of data from the diabetes control and complications trail [ J ]. Diabetes Care,2006,29 ( 2 ) :352 - 355.
  • 7The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.N Engl J Med,1993,329:977-986.
  • 8Tamborlane WV,Beck RW,Bode BW,et al.Continuous glucose monitoring and intensive treatment of type 1 diabetes.N Engl J Med,2008,359:1464-1476.
  • 9Mastrototaro J,Shin J,Marcus A,et al.The accuracy and efficacy of real-time continuous glucose monitoring sensor in patients with type 1 diabetes.Diabetes Technol Ther,2008,10:385-391.
  • 10Clark WL,Anderson S,Farhy L,et al.Evaluating the clinical accuracy of two continuous glucose sensors using continuous glucose error grid analysis.Diabetes Care,2005,28:2412-2417.

共引文献81

同被引文献81

引证文献7

二级引证文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部