期刊文献+

三相逆变器的结构能控性分析

Study on structural controllability of three-phase three-wire inverter
下载PDF
导出
摘要 针对三相四线制逆变器的结构能控性问题,将其建模为一类状态变量变化连续的混杂系统,同时将混杂系统模型与图论方法结合起来,提出了适用于电力电子变换器结构能控性分析方法,并利用该方法分析了三相四线制逆变器的结构能控性,最后用切换线性系统能控性理论与仿真,验证了图论方法分析的可行性与正确性。 In order to study the controllability of three-phase three-wire inverter, the inverter was modeled as atype of hybrid system which had no abrupt change of the state variables. Thereafter, based on the hybrid systemmodel, the structural controllability of the three-phase three-wire inverter was studied by the graph theoryapproach. The research results show that the three-phase three-wire inverter is structural controllable.Simulations based on simulink was conducted to verify the correctness of the analysis.
出处 《佛山科学技术学院学报(自然科学版)》 CAS 2016年第5期6-10,共5页 Journal of Foshan University(Natural Science Edition)
基金 国家自然科学基金资助项目(51277030) 广东省自然科学基金资助项目(2016A030310241) 广东省高等学校高层次人才资助项目(2050205-194)
关键词 三相四线制逆变器 结构能控性 切换线性系统 three-phase four-wire inverter structural controllability switched system
  • 相关文献

参考文献3

二级参考文献40

  • 1万山明,吴芳,黄声华.三相四桥臂电压源高频链逆变器[J].中国电机工程学报,2005,25(12):47-51. 被引量:26
  • 2张宇,段善旭,康勇,陈坚.基于瞬时对称分量的三相逆变器特性分析[J].中国电机工程学报,2005,25(17):15-20. 被引量:21
  • 3丘东元,张波.谐振开关电容变换器中潜电路现象的研究[J].中国电机工程学报,2005,25(21):34-40. 被引量:25
  • 4张波.电力电子学亟待解决的若干基础问题探讨[J].电工技术学报,2006,21(3):24-35. 被引量:30
  • 5Cross A M, Evans P D, Forsyth A J.DC link current in PWM inverterswith unbalanced and non-linear loads[J].IEE Proceedings-Electr.Appl., 1992, 146(6): 620-626.
  • 6Yao Guijun, Phillips S, Norum L.Three-phase inverters-analysis ofability to maintain symmetrical output voltages [C].IEEE Proceedingof the IECON' 93 , NovemberMaui, Hanaii, USA, 1993.
  • 7Hsu P, Behnke M.A three-phase synchronous frame controller forunbalanced load [C].IEEE-PESC' 98 Record, Fukuoka, Japan, 1998,2(5): 1369-1374.
  • 8BoruppU, EnjetiPN, BlaabjergF.Anewspace-vector-basedcontrolmethod for UPS systems powering nonlinear and unbalanced loads[J].IEEETrans.Ind.Appl., 2001, 37(6): 1864-1870.
  • 9Ei-Barbari S, Hofmann W.Digital control of a four leg inverter forstandalone photovoltaic systems with unbalanced load [C].IEEEProceeding of the IECON'2000, Nagoya, 2000.
  • 10Segura A N, Aguilar G M.A novel four-branches-inverter-based-active-filter for harmonic suppression and reactive compensation of anunbalanced 3-phase 4-wires electrical distribution systems, feedingAC/DCloads[C].IEEE-PESC'2000Record, Galway, UK, 2000.

共引文献134