期刊文献+

超声、钼靶X线及其联合应用诊断乳腺癌准确性的Meta分析 被引量:7

The accuracy of ultrasonography,molybdenum target x-ray and its combined application on diagnosis of breast cancer: A meta-analysis
下载PDF
导出
摘要 目的:采用Meta分析方法评价超声、钼靶以及联合应用在乳腺癌诊断中的临床价值。方法:计算机检索Pub Med、Web of Science、The Cochrane Library、万方数据库、中国知网、中国生物医学文献数据库,并辅以手工检索,获取超声和钼靶在乳腺癌诊断的相关文献。依据诊断准确性研究的质量评估(QUADAS-2)工具进行文献质量评价。利用Meta-Disc1.4和Rev Man 5.2软件对超声和钼靶诊断乳腺癌的敏感性(SEN)、特异性(SPE)、阳性似然比(+LR)、阴性似然比(-LR)、诊断比值比(DOR)进行合并分析,并计算综合受试者工作特征(SROC)曲线下面积。结果:Meta分析结果显示,以术后病理检查为金标准,乳腺超声诊断乳腺癌的SEN合并为0.85(95%CI:0.84,0.86),SPE合并为0.93(95%CI:0.92,0.93),DOR为20.35(95%CI:13.62,30.4);钼靶X线诊断乳腺癌的SEN合并为0.81(95%CI:0.80,0.83),SPE合并为0.97(95%CI:0.97,0.97),DOR为19.49(95%CI:11.29,33.66);乳腺超声联合钼靶X线诊断乳腺癌的SEN合并为0.94(95%CI:0.93,0.95),SPE合并为0.93(95%CI:0.92,0.94),DOR为89.24(95%CI:46.14,172.63)。结论:乳腺超声和钼靶X线诊断乳腺癌的准确性较高,两者效果相当,联合应用更能有效地提高诊断乳腺癌的准确性。 Objective:To evaluate the clinical value of ultrasound, molybdenum target x-ray and its combined application for diag-nosis of breast cancer by meta-analysis. Methods: The relative studies of ultrasound, molybdenum target x-ray for diagnosis of breast can-cer were systematically searched in the following databases: PubMed(1966-2015.4), Web of Science(1980-2015.4), Cochrane Library (2015.4), Wan Fang databases(1990-2015.4), CNKI(1994-2015.4),CBM(1978-2015.4).The quality assessment of diagnostic accuracy studies(QUADAS-2) items were used to evaluate the quality of included studies. Meta-analysis was conducted by using Meta-disc 1.4 and Rev-Man5.2 software, such as sensitivity(SEN), specificity(SPE), positive likelihood ratio(+LR), negative likelihood ratio(-LR), diagnosis odds ra-tion (DOR), etc. And then draw summary receiver operating characteristic(SROC) and calculate the area under the curve(AUC). Results:With postoperative pathologic result as the gold standard, meta-analysis results showed that SEN, SPE, DOR, AUC of ultrasound in diagnosis for breast cancer were 0.85(95%CI:0.84, 0.86), 0.93(95%CI:0.92, 0.93), 20.35(95%CI:13.62, 30.4) respectively;and SEN, SPE, DOR, AUC of molybdenum target x-ray in diagnosis for breast cancer were 0.81(95%CI:0.80, 0.83), 0.97(95%CI:0.97, 0.97), 19.49(95%CI:11.29, 33.66) respectively;SEN, SPE, DOR, AUC of both combination in diagnosis for breast cancer were 0.94(95%CI:0.93, 0.95), 0.93(95%CI:0.92, 0.94), 89.24(95%CI:46.14, 172.63) respectively. Conclusion:Ultrasound and molybdenum target x-ray has almost the same high accuracy and ef-fects for diagnosis of breast cancer, and its combined application can effectively improve the accuracy of the diagnosis of the breast cancer.
出处 《甘肃医药》 2016年第10期731-737,共7页 Gansu Medical Journal
基金 甘肃省卫生行业科技计划管理项目(项目编号:GWGL2010-4)
关键词 乳腺癌 超声 钼靶X线 BI-RADS META分析 breast cancer ultrasound molybdenum target x-ray BI-RADAS meta-analysis
  • 相关文献

参考文献13

二级参考文献111

共引文献302

同被引文献71

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部