期刊文献+

EAST中性束注入器电源故障实时监测系统设计 被引量:2

Design of Fault Signal Real-time Monitoring System of NBI Power System
下载PDF
导出
摘要 为实现对EAST中性束注入(Neutral Beam Injection,NBI)器电源系统在线运行状态进行实时监测,论文提出了一个基于FPGA、百兆以太网和C#用户终端的全光纤组网实时故障态监测系统解决方案。系统对中性束注入装置各电源的故障态以及输出波形进行实时采集和组网传输,并拥有用户终端进行监测和控制操作,在中性束装置实验运行测试中获得了较好的结果。系统对于大量分散信号的分布采集和远程监测系统设计具有一定参考价值。 To monitor online real - time running state of EAST - NBI power system, a fault signal real - time monitoring system is provided based on FPGA, Ethernet and C # user terminal. The system achieves real - time acquisition and transmission of fault signals and output waveforms of NBI power system, also has the interface software of PC for remote monitoring. This system is tested in recent operation of EAST - NBI and shows good results, which has reference value for acquisition and real - time remote monitoring systems of a large number of scattered distribution of signals.
出处 《核电子学与探测技术》 CAS 北大核心 2016年第5期496-502,共7页 Nuclear Electronics & Detection Technology
基金 国家磁约束核聚变发展研究(2013GB101003) 国家自然科学基金(11575240 11505224 11505225)资助
关键词 分布数据采集 远程传输 实时 现场可编程逻辑门阵列 data acquisition remote transmission real - time FPGA
  • 相关文献

参考文献8

二级参考文献59

  • 1屠三益,唐德光,沈世湲,陆培成,于念英.上海市35kV、110kV、220kV变电站最佳容量探讨(一)[J].上海电力,1996,0(1):19-22. 被引量:1
  • 2罗杰,谢自美.电子线路设计.实验.测试(4版)[M].电子工业出版社,2010,9.
  • 3曾繁泰 陈美金.VHDL程序设计(第二版)[M].北京:清华大学出版社,2001..
  • 4TI公司.TLC3574 data sheet[Z].,2001..
  • 5TI公司.Switched-capacitor ADC analog input calculations—application report[Z].,1998..
  • 6赵俊超.集成电路设计VHDL教程[M].北京:希望电子出版社,2002.
  • 7马岚.高速数字设计[M].北京:电子工业出版社,2003.
  • 8Ahera公司. Introduction to Quartus Ⅱ[ S ], 2004.
  • 9Altera 公司. DDR SDRAM Controller White Paper[ S ] ,2000.
  • 10佚名.STM32开发指南V1.0库函数版本[EB/OL].[2013.02.18].http ://wenku.baidu.com.