期刊文献+

设计参数对冷库地坪通风防冻系统性能的影响研究 被引量:5

Study on the effect of the design parameters on the performance of cold storage floor antifreezing ventilation system
原文传递
导出
摘要 为研究冷库地坪通风防冻系统性能的影响因素,并为系统的设计与优化提供理论依据,建立了冷库地坪通风防冻系统计算模型,以地面加热量和地面加热层温度为评价指标,讨论了支风道内流速、支风道间距、支风道管径及通风加热装置每日运行时间对系统性能的影响。研究结果表明:支风道内流速、支风道间距、支风道管径及通风加热装置每日运行时间对冷库地坪通风防冻系统的性能均有不同程度的影响。 To investigate the influence factors of the performance and provide the theoretical basis for the design as well as optimization of the cold storage floor antifreezing ventilation system, a mathematical model was established. The heating capacity of the ground and the temperature of the ground heating layer were taken as the evaluation index. The effects of the air velocity, the spacing of ducts, the diameter of ducts and the running time on the performance of cold storage floor antifreezing ventilation system were discussed. The resuhs show that the air velocity, the spacing of ducts, the diameter of ducts and the running time all have different degrees of effects on the performance of cold storage floor antifreezing ventilation system.
出处 《低温与超导》 CAS 北大核心 2016年第10期58-61,共4页 Cryogenics and Superconductivity
基金 河南省高等学校重点科研项目(15A560004) 河南工业大学河南省省属高校基本科研业务费专项资金(2015QNJH05) 河南工业大学高层次人才基金(2014BS015) 河南工业大学2015年优培课程<暖通空调>项目资助
关键词 通风防冻 流速 风道间距 管径 运行时间 Antifreezing ventilation, Air velocity, Spacing of ducts, Diameter of ducts, Running time
  • 相关文献

参考文献10

二级参考文献15

共引文献19

同被引文献29

引证文献5

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部