针对目前计算机联锁系统等信号控制系统中直流稳压电源故障高发情况,着重对控制系统中高品质直流稳压电源的可靠性及规范使用进行论述,以此指导系统设计,正确使用直流稳压电源,使其使用寿命得到有效延长。
As far as a high incidence of AC/DC power supply failure in signal control equipment like interlocking system at present is concerned,the reliability and specification usage of high quality AC/DC stabilized power supply in railway control system is expounded so as to guide system design in using AC/DC regulated power supply in a correct way for extended service life of the power supply.