核电厂辅助给水汽水分离器疏水管失效原因分析 被引量:1

Failure Analysis of Drain Pipe of Auxiliary Feedwater Moisture Separator for Nuclear Power Plant
下载PDF
导出
摘要 国内某核电厂大修时,发现辅助给水汽水分离器的疏水管道有大量的腐蚀产物,造成排水不畅。本文从管道结构、腐蚀产物成分分析和水质分析等方法对管道堵塞原因进行了分析。分析结果表明腐蚀产物主要来自于生活饮用水系统,生活饮用水系统在发生p H值和温度的变化时析出固体粒子,固体粒子在管道弯头不断沉积最终造成管道堵塞。 There is so large amount o f corrosion products in drain pipe that auxiliary feedwater moistureseparator cannot work well for nuclear power plant. In this article, structure o f pipe, elementary compositiono f corrosion products, water quality are analyzed. Results indicated that corrosion products mainly comefrom domestic water system. The solid particles are precipitated from domestic water system with changingo f pH and temperature. The solid particles are deposited continuously in elbow causing pipe plugging finally.
出处 《全面腐蚀控制》 2016年第10期29-32,83,共5页 Total Corrosion Control
关键词 辅助给水汽水分离器 疏水管 堵塞 成分分析 水质分析 auxiliary feedwater moisture separator drain pipe pipe plugging elementary composition water quality
  • 相关文献

参考文献1

二级参考文献4

  • 1严莲荷主编.水处理药剂及配方手册[M].北京:中国石化出版社,2003,182-184,202-204.
  • 2Somerscaies E.F.D., Kundsen J.G. Fouling of Heat Transfer Equipment[M]. Hemisphele Pub. Co., 1981.
  • 3HG/T3729-2004射频物理场水处理设备技术条件[S].
  • 4王同善.应急柴油机充气冷却水系统典型故障的处理[J].中国核电,2011,4(3):268-272. 被引量:6

同被引文献2

引证文献1

相关作者

内容加载中请稍等...