摘要
冰蓄冷技术既能够节省运行费用,又能够移峰填谷缓解用电矛盾,但因其技术原因得不到推广。新型融冰机组可模块化预制,将冰蓄冷技术和集中空调系统有机结合,优化运行效果。经过能耗分析计算,不同的组合模式可降低运行费用15%-30%。
Ice storage technology can not only save operation costs, but also ease the peak shift to fill in the valley so as to resolve the electricity issue, but it can not be popularized because of technical reasons. This new type of ice-melting unit can combine the ice storage technology with the central air-conditioning system and optimize the operation effects through modularized precasting. After energy consumption analysis and calculation, different combination modes can reduce operation costs by 15%-30% .
出处
《制冷与空调》
2016年第10期10-14,共5页
Refrigeration and Air-Conditioning
关键词
集中空调
冰蓄冷
融冰机组
central air-conditioning
ice storage
ice-melting unit