摘要
对采用不同结构分流器的空调器整机性能进行测试,结果表明:分流器内部结构设计及其摆放方式对换热器换热效果影响很大,在不更换换热器的前提下,合理设计分流器可以使空调器的制冷量和能效有较大提升,且运行更加可靠。
The performance of air conditioner with different splitter structure is tested. The results show that the internal structure design and placement method of splitter have a great effect on heat transfer performance. On the premise of the same evaporator, the reasonable design of splitter can promote the cooling capacity and energy efficiency of air conditioner, and the air conditioner can operate more reliably.
出处
《制冷与空调》
2016年第10期26-28,共3页
Refrigeration and Air-Conditioning
关键词
空调器
分流器
射流环
摆放方式
换热器
air conditioner
splitter
jet-loop
placement method
heat exchanger