摘要 目的探讨生物学变异允许总误差在血脂检测中的质量管理。方法对2015年参加原卫生部脂类正确度验证的胆固醇(CHOL)、三酰甘油(TG)、高密度脂蛋白(HDL-C)、低密度脂蛋白(LDL-C)进行σ分值、质量目标指数(QGI)、优先改进措施及性能评定等指标进行评价,对成绩不理想的CHOL作原因分析。结果生物学变异设定的质量规范3个层次,当允许总误差处于适当的水平时,TG、HDL-C、LDL-C的σ分值已满足6,无需改进。而CHOL的分析性能为差,需优先改进正确度。当允许总误差处于最佳水平时,4个项目中只有TG的σ分值可达到"良",可进行精密度改进。当允许总误差处于最低水平时,TG、HDL-C、LDL-C的σ分值远大于6,分析性能达到"优",CHOL的σ分值(2.9)已接近3σ水平,应从正确度进行纠正。结论 6σ质量理论可反映检测项目的性能,且能有效提高分析质量。 Objective To study on the application of biological variation total allowable error in quality management of serum lipid detection.Methods Theσscore,quality goal index(QGI),priority improvement measures and performance evaluation of lipid accuracy criteria were evaluated,including cholesterol(CHOL),triglyceride(TG),high density lipoprotein(HDL-C),low density lipoprotein(LDL-C),which included in the standard of accuracy of the Ministry of Health in 2015.The reason for unsatisfactory results of cholesterol(CHOL)test were analyzed.Results Based on the three levels of quality specifications derived in biological variation,when the total allowable error was located at an appropriate level,theσscore of TG,HDL-C,LDL-C reached 6,it was not required for improvement.While the score of CHOL performance analysis was poor,accuracy was required to give priority to improving.When the total allowable error reached the best level,only theσscore of TG achieved"good"in the four items,improvement of precision was needed.When the total allowable error was located at the lowest level,theσscore of TG,HDL-C,LDL-C was greater than 6,the score of performance analysis reached the"excellent".Theσscore of CHOL(2.9)had been closen to 3σ,accuracy was required to be corrected.Conclusion The biological variation derived total allowable error is easy to meet the requirements of the quality management in serum lipid determination by current technologies and methods.The theory of 6σquality can reflect the performance of detection indexes,and improve the quality of analysis effectively.
出处 《国际检验医学杂志》 CAS 2016年第19期2708-2709,2712,共3页 International Journal of Laboratory Medicine
关键词 血清脂质 生物学变异 总允许误差 准确性 精密度 serum lipid biological variation total allowable error accuracy precision
  • 相关文献

参考文献4

二级参考文献42

共引文献109

同被引文献20

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部