期刊文献+

温度计套管性能研究 被引量:4

Study on Thermowell Performance
下载PDF
导出
摘要 现有的温度计套管性能分析主要集中在固定频率和激励频率关系上,忽略了套管的受力情况。根据ASME PTC 19.3TW—2010,引入了频率限制、稳态应力限制、动态应力限制、流体静力学应力极限四个准则,判断套管是否适用于各种工况,并通过计算实例验证方法可行性。同时,分析了套管几何尺寸对部分套管性能的影响,对温度计套管的选型设计具有一定的参考价值。 Evaluation on thermowell is mainly focused on relationship between fixed frequency and vortex shedding frequency. Stress sustained by thermowell is often ignored. Based on ASME PTC 19. 3 TW -2010, four criterions of frequency limitation, steady-state stress limitation, dynamic stress limitation and hydrostatic pressure limitation are introduced to determine if a thermowell is applicable or not for all kinds of working condition. The validity of the method is verified with an actual case calculation. Effect of geometrical size on thermowell performance is also investigated. It can be used as some guidelines for thermowell selection.
出处 《石油化工自动化》 CAS 2016年第5期54-57,60,共5页 Automation in Petro-chemical Industry
关键词 温度计套管 频率限制 稳态应力 动态应力 流体静力学应力极限 thermowell frequency limitation steady state stress dynamic stress hydrostatic stress limitation
  • 相关文献

参考文献4

二级参考文献20

  • 1API 551 - 1993, Process Measurement Instrumentation
  • 2ASME PTC19.3-2004 Part3 ,Temperature Measurement
  • 3ASME Boiler and Pressure Vessel Code, Section Ⅷ, Unfired Pressure Vessels
  • 4范玉久,朱麟章.化工测量及仪表.北京:化学工业出版社,2001.278-280
  • 5陆德明,张振基,黄步余.石油化工自动控制设计手册[M].3版.北京:化学工业出版社,2000.
  • 6汉建德,郭峰,赵琼.温度计套管的计算[J].石油化工自动化,2007,43(4):69-70. 被引量:15
  • 7于忠国.温度测量误差几点分析[J].石油化工自动化,2007,43(4):77-79. 被引量:5
  • 8范玉久.化工测量及仪表[M].北京:化学工业出版社,2001:56-78.
  • 9ASME PTC 19.3-1974 (R1998) ,Temperature Measurement.
  • 10王魁汉.温度测量实用技术[M].北京:机械工业出版社,2006.