摘要
基于相关标准要求,分析两种电器插座保护门因结构设计缺陷而未能达到防触电保护功能的具体原因,提出改进设计方案,确保改进后的插座防触电保护功能顺利实现。
Based on the requirements of relevant standards, this paper analyzes structure design flaws of two kinds of electrical socket protective doors, which results in failure in protection against electric shock, then puts forward the improvement scheme, to ensure that the improved socket can protection against electric shock smoothly.
作者
王业银
Wang Yeyin(Panasonic Information Instrument (Shanghai) Co., Ltd. Shanghai, 201108)
出处
《电动工具》
2016年第5期7-9,共3页
Electric Tool
关键词
插座保护门
防触电保护
结构设计
Electrical socket protective doors
Protection against electric shock
Structure design