期刊文献+

紫外辐射测量技术现状与发展趋势(下) 被引量:1

Present Situation and Development Trend of Ultraviolet Radiation Measurement Technology(Ⅱ)
原文传递
导出
摘要 近年来,紫外技术在国民经济的许多领域得到广泛应用,发挥着许多不可替代的作用。为进一步提升紫外技术及其应用,结合表征紫外辐射性能的主要参数,现有紫外辐射测试技术及仪器,影响紫外辐射测量准确度的因素,对紫外辐射测量技术的现状和发展趋势进行了讨论,以期为深入研究紫外技术提供测量技术的基础保障。 In recent years, with the extensive application of ultraviolet (UV) technology in many areas of the national economy, the ultraviolet (UV) technology plays an irreplaceable role. To further enhance the UV technology and its application, combing the main parameters of violet radiation properties characterization, the existing UV radiation measurement technology and instruments, and the effects for accuracy factors of UV radiation measurements, the present situation and development trend of UV radiation measurement technology are discussed. It hopes to provide the basic condition for the further study of UV technology.
作者 廖辉 陈伟雄 熊志芳 何志明 LIAO Hui CHEN Weixiong XIONG Zhifang HE Zhiming(Guangdong Engineering and Technology Research Center of UV Disinfection and Purification Apparatus, Foshan 528500, China Foshan Comwin Light & Electricity Co., Ltd., Foshan 528500, China Foshan Electrical & lighting Co., Ltd., Foshan 528500, China)
出处 《中国照明电器》 2016年第9期36-39,共4页 China Light & Lighting
关键词 紫外辐射 测量 发展趋势 ultraviolet radiation measurement development trend
  • 相关文献

参考文献4

二级参考文献18

  • 1马生柏,汪斌.有机废气处理技术研究进展[J].内蒙古环境科学,2009,21(2):55-58. 被引量:27
  • 2唐运雪.有机废气处理技术及前景展望[J].湖南有色金属,2005,21(5):31-35. 被引量:58
  • 3Qualls R G,Johnson J D. Bioassay and dose measurement in UV disinfection [ J ]. Appl Environ Microbiol, 1983,45 (3) :872 -877.
  • 4Linden K G, Darby J L. Estimating effective germicidal dose from medium pressure UV lamps [ J]. J Environ Eng, 1997,123( 11 ) :1142 - 1149.
  • 5Li M K, Qiang Z M. An on-line monitoring system using micro-fluorescent silica detectors for determination of three key operating parameters of a UV facility[ A]. Pro- ceedings of the 2012 IWA World Water Congress & Exhi- bition[ C ]. London : IWA Pulishing,2012.
  • 6Ducoste J, Linden K. Determination of ultraviolet sensor location for sensor set-point monitoring using computa- tional fluid dynamics [ J ]. J Environ Eng Sci, 2005,4 (S1) :S33 -S43.
  • 7Li M K,Qiang Z M,Li T G,et al. In situ measurement of UV fluence rate distribution by use of a micro fluorescent silica detector [ J ]. Environ Sci Technol, 2011,45 (7) : 3034 - 3039.
  • 8Li M K, Qiang Z M, Bolton J R, et al. Impact of reflection on the fluence rate distribution in a UV reactor with vari- ous inner reactor walls as measured using a micro-fluores- cent silica detector[ J ]. Water Res, 2012,46 ( 11 ) : 3595 - 3602.
  • 9Li M K, Qiang Z M, Li T G,et al. In situ measurement ofUV fluence rate distribution by use of a micro fluorescent silica detector [ J ]. Environ Sci Technol, 2011,45 ( 7 ) : 3034 - 3039.
  • 10Li M K, Qiang Z M, Bohon J R ,et al. Impaet of reflection on the fluence rate distribution in a UV reactor with vari- ous inner reactor walls as measured using a micro-fluores- eent silica detector[ J ]. Water Res, 2012,46 ( 11 ) : 3595 - 3602.

共引文献21

同被引文献12

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部