摘要 从RD 8000地下管线探测仪的工作原理出发,阐述了RD 8000地下管线探测仪的使用方法及不同使用方法之间的优缺点,并对地下管线探测时的误差进行了分析,对比分析了峰值法与谷值法定位偏差大小,为使用RD 8000在实际地下管线探测中提出了几点建议。 Base on the work principle of RD 8000 underground pipeline detector, this paper expounds the use of different methods and the advantages and disadvantages between RD 8000 underground pipeline detector using methods, analyzes the error of the underground pipeline detection, and analyzes the locating error size in Peak and Valley locating methods. Finally, some suggestions are put for the detection of the actual underground pipeline by using RD 8000.
作者 徐教煌 Xu J iaohuang(China Ordnance Industry Survey, Design ~ Research Institute, Beijing 100053, China)
出处 《岩土工程技术》 2016年第4期199-202,共4页 Geotechnical Engineering Technique
关键词 地下管线探测 峰值法 谷值法 误差 旁线干扰 underground pipeline deteetiom Peak method~ Valley method~ error~ interference from nearby pipelines