期刊文献+

4π BaF_2装置的触发系统研究 被引量:3

Study of Trigger System for γ-ray Total Absorption BaF_2 Facility
下载PDF
导出
摘要 设计了一套γ全吸收型BaF_2探测装置,用于中子辐射俘获反应截面的在线测量,其中信号测量部分采用了基于高速采集卡的数字化脉冲波形采集技术。并设计了一套触发系统,由触发单元产生的信号作为数据获取系统的外触发控制数据采集,以在数据测量过程中剔除绝大多数本底事件。触发系统采用了符合测量技术,通过多通道、多参数之间的符合测量,实现释放瞬发级联γ射线的中子俘获反应事件的判选和本底的剔除。本文对触发系统的电路设计和实验测试进行了阐述。 The γ-ray total absorption BaF_2 facility was designed to measure the crosssection of neutron radiative capture reaction by online method.The data acquisition system was developed based on flash analog-to-digital converter with an ability of digital waveform acquisition.The trigger system,in which the coincidence measurement technology between multi-channel and multi-parameter was applied,was used to control the data acquisition so as to suppress most of background event,by triggering the data acquisition system.In this paper,the circuit design and experimental test of the trigger system were described.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2016年第10期1866-1870,共5页 Atomic Energy Science and Technology
基金 中国原子能科学研究院核数据重点实验室基金资助项目(9140C740401140C74001)
关键词 γ全吸收型BaF2探测装置 触发系统 FADC 数据采集 γ-ray total absorption BaF2 facility trigger system FADC data acquisition
  • 相关文献

参考文献4

二级参考文献24

  • 1竺礼华,候龙,黄正德,丁大钊.BaF_2性能测试及其应用[J].原子能科学技术,1994,28(2):123-128. 被引量:8
  • 2LAVAL M, MOSZYNSKI M, ALLEMAND R, et al. Barium fluoride-inorganic scintillator for subnano-second timing[J]. Nucl Instrum Methods, 1983, A206: 169-176.
  • 3WISSHAK K, GRUBER K, KAEPPLER F, et al. The Karlsruhe 4π barium fluoride detector [J]. Nucl Instrum Methods, 1990, A292 (3) : 595-618.
  • 4复旦大学,清华大学和北京大学.原子核物理实验方法[M].3版.北京:原子能出版社,1997:20-21.
  • 5贺国珠.(n,γ)反应截面测量用4πBaF2闪烁体探测器研制[D].兰州:兰州大学,2006.
  • 6SHEETS S A, AGVAANLUVSAN U, BECKER J A, et al. Test of the statistical model in 96 Mo with the BaF2γ calorimeter DANCE array [J]. Physical Review C, 2009, 79(2) : 1-9.
  • 7LAVAL M, MOSZYNSKI M, ALLEMAND R, et al. Barium fluoride-inorganic scintillator for subnano-second timing[J].Nucl Instrum Methods A, 1983, 206: 169-176.
  • 8AMORINI F, ROONEY B D, DINWIDDIE D R, et al. Analysis of digital timing methods with BaF2 scintillators[J]. Nuclear Instruments and Methods in Physics Research A, 2003, 505 : 324- 327.
  • 9Agilent Technologies. Programmers guide [S/ OL]. Agiient Acqiris Instruments, 2007[2007- 09-22]. http..//www, acqiris, com.
  • 10MARRONE S, BERTHOMIEUX E, BECVAR F, et al. Pulse shape analysis of signals from- BaF2 and CeF3 scintillators for neutron capture experiments[J]. Nuclear Instruments and Methods in Physics Research A, 2006, 568: 904-911.

共引文献16

同被引文献17

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...