期刊文献+

DP-Ⅰ型自动温湿控制设备性能试验

Experiment on the Performance of DP-Ⅰ Type Automatic Temperature and Humidity Control Equipment
下载PDF
导出
摘要 为验证DP-Ⅰ型自动温湿控制设备在育苗大棚的应用效果,在新民县湖台镇车古营子村水稻育苗基地进行试验。试验结果表明:机具的可靠性、自锁性、安全性、温度传感器准确度、温控系统准确度及土壤相对湿度等指标均符合规定。 In order to verify the effect of DP-I type automatic temperature and humidity equipment working in seedling shed, the experiment was conducted in rice seedling base located in Cheguyingzi Village Hutai Town Xinmin Country. The results showed that: the indexes of the equipment , such as reliability, self-locking, safety, accuracy of temperature sensor, accuracy of temperature control system and relative soil moisture all comply with regulations.
作者 聂影
出处 《农业科技与装备》 2016年第7期13-15,共3页 Agricultural Science & Technology and Equipment
基金 水稻适宜机械化工厂化育苗技术研究与示范(20141740) 国家现代农业产业技术体系辽宁水稻创新团队建设项目(辽农科﹝2013﹞271号)
关键词 自动温湿控制设备 卷膜器自锁性 温度传感器 自动温控系统 automatic temperature and humidity control equipment self-locking of film reeler temperature sensor automatic temperature control system