摘要 配电网设备可靠性地区差异大,故障诊断自动化程度低.为保证能够快速精确地做出故障诊断,提出了一种基于改进时间模糊Petri网配电网故障诊断新方法.首先利用保护断路器信息、报警信息、状态信息和电气量来纠正断路器动作信息,确定停电区域;然后根据动作的断路器能够保护的范围确定可疑故障元件,利用带时标的保护断路器信息,针对可疑故障元件建立时间模糊Petri网模型进行故障诊断.模拟测试表明,此方法提高了配电网故障诊断速度和准确度,具有良好的实用价值. In distribution network, the equipments in different regions have different reliabilities, and the automation of fault diagnosis is at low level. In order to make the fault diagnosis quick and accurate, a new method of distribution network fault diagnosis was presented based on improved time fuzzy Petri net. Firstly, the information of breakers with the switch and electrical information were corrected, and the areas where power collapse were found out. Then, according to the range that the breaker can protect, the suspicious fault elements were found out, and the time fuzzy Petri net model for suspicious fault elements with time-tag information was built. Finally the diagnosis results were given. The simulation results show that the efficiency and accuracy of fault diagnosis are improved. In addition, the fault process can be shown for dispatchers with good practical application value. © 2016, Editorial Department of Journal of Northeastern University. All right reserved.
出处 《东北大学学报(自然科学版)》 EI CAS CSCD 北大核心 2016年第11期1526-1529,共4页 Journal of Northeastern University(Natural Science)
基金 国家自然科学基金资助项目(61203026) 国家自然科学基金重点资助项目(61433004) 中央高校基本科研业务费专项资金资助项目(N140404003)
关键词 时间模糊 PETRI网 报警信息 故障诊断 配电网 Electric power distribution Failure analysis Fuzzy systems Petri nets
  • 相关文献

参考文献2

二级参考文献16

共引文献130

同被引文献66

引证文献8

二级引证文献96

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部