摘要
介绍了硫酸-磷酸-硝酸混酸溶解试样,钒铝中间合金中钒量的高锰酸钾氧化-硫酸亚铁铵滴定法。考察了试样分解方法、钒的氧化条件、尿素用量、亚硝酸钠用量、溶液酸度的影响及共存离子干扰等一系列条件对钒测定结果的影响,确定了最佳实验条件。运用此法对含钒量不同的6个钒铝合金样品中钒量进行11次测定,含钒量从50%到85%,相对标准偏差(RSD)均不大于0.2%,加标回收率在98.2%~102.5%。通过与其他7家实验室间的比对试验,证实该法测定结果无明显系统偏差,适于推广应用。
A method for the determination of Vanadium in Vanadium-Aluminium master alloys by KMnO4 -Ferrous titration method is presented .The sample was digested by H2SO4-H3PO4-HNO3. The influence of the method for sample digestion; the amount of KMnO4 and NaNO2; the interference of co-existence elements were discussed so as to confirm the best condition. The proposed method was applied to determine the Vanadium contents in six Vanadium-Aluminium master alloy samples whose Vanadium content was different from 49.45% to 83.33%. The results showed that the relative standard deviations(n=11) were all about 0.2%, and the recoveries were in the range of 98.2%~102.5%.Compared with 7 different laboratories , the results were consistent without significant deviation. This method has the advantages of fast,accurate and a wide analytical range. It is suitable for determination Vanadium in Vanadium-Aluminium master alloys.
出处
《稀有金属材料与工程》
SCIE
EI
CAS
CSCD
北大核心
2016年第10期2729-2733,共5页
Rare Metal Materials and Engineering
基金
有色金属行业标准制定项目(2013-1637T)
关键词
钒铝合金
钒
高锰酸钾氧化-亚铁滴定法
vanadium-aluminium alloy
vanadium
KMnO4-ferrous titration method