摘要
老旧冷却塔服役时间长,建筑结构出现不同程度的老化或破损,结合具体工程实例,详细阐述老旧冷却塔结构的检测内容和方法,采用Midas/gen软件进行冷却塔结构分析,并对冷却塔的可靠性进行评定,提出初步加固方法和整改意见。
Old cooling tower long service time,building structures with varying degrees of aging or damaged,concrete engineering examples,detailed description of the content and method for the detection of old cooling tower structure,by midas/gen software for cooling tower structure analysis,and the reliability of the cooling tower are evaluated,and put forward a preliminary method of reinforcement and rectification.
出处
《建筑技术开发》
2016年第9期34-35,63,共3页
Building Technology Development
关键词
冷却塔
钢筋混凝土结构
检测鉴定
处理加固
cooling tower
reinforced concrete structure
detection and identification
treatment and reinforcement