期刊文献+

KED-ICP-MS测定天然饮用泉水中的18种元素含量 被引量:9

Determination of 18 Elements in Drinking Spring Water by Inductively Coupled Plasma-mass Spectrometry with Collision Cell Technology
下载PDF
导出
摘要 建立碰撞反应池-电感耦合等离子体质谱(KED-ICP-MS)测定天然饮用泉水中的K、K、Na、Ca、Mg、Fe、Mn、Cu、Zn、Li、Sr、Se、As、Cd、Ni、Pb、Ba、Cr、Hg等18种元素含量的方法,采集的天然饮用泉水经过酸化处理后,采用碰撞反应池技术进行测定,通过通入氦气的碰撞反应来消除分子离子干扰,使得检测结果更加准确。试验表明,测定18种元素的线性相关系数均〉0.999,相对标准偏差为0.39%~4.97%,各元素的加标回收率均在85.4%~115.0%之间,测定各元素的标准参考物质,测定值均在标准值范围内。 The method for determination of 18 elements including K,Na,Ca,Mg,Fe,Mn,Cu,Zn,Li,Sr,Se,As,Cd, Ni,Pb,Ba,Cr,Hg in drinking spring water by inductively coupled plasma mass spectrometry(ICP-MS) based on collided reaction cell technology was established.Nitric was added to the collected drinking spring water and the samples could be determined by inductively coupled-plasma mass spectrometry based on collided reaction cell technology.Helium was used as collision to eliminate mass spectroscopic interference .The results showed that the linear correlation coefficients were more than 0.999.The relative standard deviations (RSD) were 0.39%-4.97%and the recoveries for the spiked samples ranged from 85.4%to 115.0%,The analysis results of stan-dard reference materials was satisfactory.
作者 蒋慧 雷宁生 黎林 钟格梅 JIANG Hui LEI Ning-sheng LI Lin ZHONG Ge-mei(Guangxi Center for Disease Prevention and Control, Nanning 530028, Guangxi, Chin)
出处 《食品研究与开发》 CAS 北大核心 2016年第16期151-154,共4页 Food Research and Development
基金 广西壮族自治区科技开发课题(桂科攻1298004-1) 广西医疗卫生重点科研课题(重2012053) 广西卫生厅科研课题(Z2013270)
关键词 元素 电感耦合等离子体质谱 天然饮用泉水 碰撞反应 elements inductively coupled plasma-mass spectrometry drinking spring water KED
  • 相关文献

参考文献5

二级参考文献48

  • 1戴特AR 李金英等(译).电感耦合等离子体质谱分析的应用[M].北京:原子能出版社,1998..
  • 2BARANOV V I ,TANNER S D. A dynamic reaction cell for inductively coupled plasma mass spectrometry (ICP-DRC-MS) Part 1. the rf-field energy contribution in thermodynamics of ion-molecule reactions [J]. J Anal At Spectrom, 1999, 14: 1 133-1 142.
  • 3TANNER S D, BARANOV V I. A dynamic reaction cell for inductively coupled plasma mass spectrometry(ICPDRC-MS). Ⅱ. reduction of interferences produced within the cell[J]. J Am Soc Mass Spectrom,1999, 10:1 083-1 094.
  • 4TANNER S D, BARANOV V I, VOLLKOP U. A dynamic reaction cell for inductively coupled plasma mass spectrometry(ICP-DRC-MS)Part Ⅲ. optimization and analytical performance[J]. J Anal At Spectrom, 2000, 15:1 261-1 269.
  • 5BANDURA D R, BARANOV V I, TANNER S D. Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J]. Anal Chem, 2002, 74:1 497-1 502.
  • 6ANICICH V G. A survey of bimolecular ion-molecule reactions for use in modeling the chemistry of planetary atmospheres, cometary comae, and in- terstellar clouds: 1993 supplement[J]. The Astrophysical Journal Supplement Series, 1993, 84 (2) : 215-315.
  • 7KOYANAGI G K, BARANOV V I, TANNER S D, et al. An inductively coupled plasma/selectedion-flow tube mass spectrometric study of the chemical resolution of isobaric interferences[J]. J Anal At Spectrom, 2000, 15; 1 207-1 210.
  • 8BANDURA D R, BARANOV V I, TANNER S D. Detection of ultratrace phosphorus and sulfur by quadrupole ICPMS with dynamic reaction cell [J]. Anal Chem, 2002, 74(7):1 497-1 502.
  • 9MASON P R D, KASPERS K, BERGEN M J. Determination of sulfur isotope ratios and concentrations in water samples using ICP-MS incorporating hexapole ion optics[J]. J Anal At Spectrom, 1999,14:1 067-1 074.
  • 10VANHAECKE F, BALCAEN L, DECONINCK I, et al. Mass discrimination in dynamic reaction cell(DRC)-ICP-mass spectrometry[J]. J Anal At Spectrom, 2003, 18:1 060-1 065.

共引文献150

同被引文献134

引证文献9

二级引证文献47