摘要 目的观察一种主要有效成分为体积分数17.2%的异丙醇和浓度2.8 g/L苄索氯铵的消毒湿巾对常用口腔修复器械及材料表面的清洁消毒效果。方法采用ATP生物荧光测定方法和细菌定量检测法,对某消毒湿巾用于口腔治疗中常用修复器材表面的清洁消毒效果进行检测与评价。结果用该消毒巾擦拭消毒后,光固化机把手有5份标本检出有菌生长,修复材料包装开口处有3份标本检出存活菌,消毒效果合格率100%。生物荧光法和细菌定量培养法检测结果基本一致。结论用该消毒湿巾对口腔常用修复器材外表面有明显消毒效果,并且可以用生物荧光法进行快速检测。 Objective To observe the disinfection and cleaning efficacy of a kind of disinfection wipes whose effective constitute was 17. 2% isopropyl alcohol and 2. 8 g / L benzethonium chloride on dental restoration equipment and material surface. Methods ATP bioluminescence assay bacterial quantitative detection methods were used to measure and evaluate the cleaning and disinfection effect. Results With the disinfection towel to wipe disinfection,5 specimens of light curing machine handle were detected bacteria growth. 3 specimens of repair materials were detected viable bacteria at the opening of the mouth. The qualify rate of disinfection effect was 100%. The results of the biological fluorescence method and the bacterial culture method were basically consistent. Conclusion The disinfectant has obvious disinfection effect by wiping dental restorative equipment surface,and ATP bioluminescence assay can be used for rapid detection.
出处 《中国消毒学杂志》 CAS 北大核心 2016年第10期967-969,共3页 Chinese Journal of Disinfection
基金 武警后勤学院附属医院种子基金(FYM201537)
关键词 口腔修复器械 物体表面 消毒湿巾 消毒效果 dental restoration equipment disinfectant wipes wiping disinfection disinfection effect
  • 相关文献

参考文献8

二级参考文献20

  • 1雷松蕙,杨小红,朱秀娥.口腔科消毒隔离技术与医院感染管理[J].中华医院感染学杂志,2006,16(2):186-186. 被引量:13
  • 2丁一 徐屹 等.口腔科交叉感染及控制措施.口腔设备及材料,1990,30(1):24-25.
  • 3Hansen D.ATP measurement as method to monitoring the quality of reprocessing flexible endoscopes[J].German Medical Science.2004,2:4.
  • 4Lehtinen J.Virta M,Lilius EM.Fluoro-Luminometric real-time measurement of bacterial viability and Killing[J].J Microbiol Methods.2003,55:173.
  • 5Gu MB,Min J,Larossa RA.Bacterial bioluminescence emission from recombinant Escherichia coil harboring a reca:luxCDABE fusion[J].J Biochem Biophys Methods.2000,45(1):45.
  • 6Cloquhounet AL.Simple method for the comparison of commerciavailable ATP hygiene-monitoring system[J].J Food Protect,1998,61:499.
  • 7Griffith CA,Cooper RA,Gilmore J,et al.An evaluation of hospital cleaning regimes and standards[J].Joural of Hospital Infection,2000,45:19.
  • 8Oulahal-Lagsir N.Ultrasonic methodology coupled to ATP bioluminescence for the non-invasive detection of fouling in food processing equipment-validation and application to a dairy factory[J].Journal of applied microbiology,2000,89:433.
  • 9Sigler K.Standardized system for quantifying residual dirt on medical appliances cleansed in hospital washers--disinfectors dirt detection by different methods.Folia Microbiol (Praha)[J].补充期刊名称,2003,48(1):95.
  • 10Green TA.et al Effect of chemical cleaning agents and commercial sanitizers on ATP biolumescence measurements[J].J Food Protect,1999,62:86.

共引文献126

同被引文献56

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部