期刊文献+

分光光度法测定压裂返排液中的碘化物

Determination of Iodide of Fracturing Outlet Liquid by Spectrophotometry
下载PDF
导出
摘要 本方法利用在酸性介质中,Cr_2O_7^(2-)能将I-氧化成为单质碘,生成的单质碘用氯仿萃取,在一定浓度范围内,萃取液中的碘浓度与吸光度符合朗伯—比耳定律这一规律。本方法检测精密度及准确度高,相对标准偏差小于4.63%,加标回收率在95.44%~106.47%之间。实验证明该方法具有非常强的抗干扰能力,而且操作简便,适于推广。 Using this method in acid medium, which I- can be oxi- dized as elemental iodine by Cr2O7^2-, generated by the elemental iodine with chloroform extraction, in the certain concentration range, extract iodine concentration and absorbanee are in accord with Lambert-Bill law. This method is of high detecting precision and accuracy, relative standard deviation less than 4.63%, standard addition recovery is between 95.44% and 106.47%. The experiments proves that this method has very strong anti-jamming capability and easy to operate, suitable for promotion.
作者 王玉杰
出处 《西部探矿工程》 CAS 2016年第11期21-23,共3页 West-China Exploration Engineering
基金 中国石油天然气股份有限公司重大科技专项"大庆探区非常规油气勘探开发关键技术研究与现场试验"(2012E-2603-06)
关键词 分光光度法 碘化物 压裂 返排液 返排率 地层水判别 speetrophotometry iodide fracturing outlet liquid cleanup rate formation water discrimination