GE公司EX2100励磁调节器V/Hz限制动作原因分析

Cause Analysis of V/Hz Limiter Action for GE EX2100 Excitation Regulators
下载PDF
导出
摘要 详细分析了GE公司EX2100励磁调节器V/Hz限制动作原理,找到了国内某电厂发电机励磁系统频繁误报过激磁限制的原因,确定了GE公司EX2100励磁调节器在设计方面的缺陷,并提出了相应的改进策略。 Based on detailed analysis of the operating principle of V/Hz limiter for GE EX2100 excitation regulator, the reason of frequently misstated excitation restriction occurring in the generator excitation system of a domestic power plant was found to be caused by design deficiency in the GE EX2100 excitation regulator, for which corresponding improvement measures were suggested.
作者 姜志慧 史扬 刘春梅 Jiang Zhihui Shi Yang Liu Chunmei(Beijing Taiyanggong Gas-fired Thermal Power Co., Ltd., Beijing 100028, China North China Electric Power Research Institute Co., Ltd., Beijing 100045, China Beijing Jingqiao Thermal Power Co., Ltd., Beijing 100067, China)
出处 《发电设备》 2016年第6期432-434,共3页 Power Equipment
关键词 发电机 励磁系统 V/Hz限制 低频振荡 PSS调节 power generator excitation system V/Hz limiter low frequency oscillation PSS adjustment