锅炉除尘器改造 被引量:5

Retrofit of a Boiler Dust Precipitator
下载PDF
导出
摘要 为减少锅炉烟尘排放,对原静电除尘器改造为布袋除尘器。通过计算流体力学数值模拟,布袋采用错层布置,外加均流装置辅助,以保证烟气流场的均匀。改造后粉尘排放质量浓度由99.47mg/m3降至为5.93mg/m3,除尘效率达到99.94%,达到预期目的。 To reduce the pollutants emission from a boiler, the original electrostatic precipitator was changed into bag-type dust collector, which was staggeringly arranged with auxiliary flow-equalizing device equipped to ensure the uniformity of flue gas flow. After retrofit, the emission concentration of dust has been reduced from 99.47 mg/m3 to 5.93 mg/m3 , with the dust collecting rate up to 99.94%, achieving the intended purpose.
作者 梁建敏 Liang Jianmin(Guangdong Yuehua Power Generation Co., Ltd., Guangzhou 510731, China)
出处 《发电设备》 2016年第6期435-437,共3页 Power Equipment
关键词 锅炉 布袋除尘器 boiler bag-type dust collector
  • 相关文献

参考文献2

  • 1韦健宏.黄埔发电厂6号机组除尘器效率试验报告[R].广州:广东电网公司电力科学研究院,2012.
  • 2韦健宏.广东粤华发电有限责任公司6号机组改造后布袋除尘器除尘效率试验报告[R].广州:广东电网公司电力科学研究院,2014.