期刊文献+

铝箔分辨法测量钍射气研究 被引量:2

Study on the Performance of Discriminating Method Using Aluminum Foil to Measure Thoron Concentration
下载PDF
导出
摘要 为了实现^(222)Rn和^(220)Rn的分辨测量,研究确定了α射线损失能量与铝箔阻挡厚度的关系,利用氡子体发射的6.00 MeV(218Po)和7.69 MeV(214Po)α射线进行了实验验证,并确定了氡钍分辨的铝箔较优阻挡厚度为46.60μm。将包裹该厚度铝箔的探测器置于220Rn室内开展照射实验,得到钍射气及其子体的刻度系数分别为0.53 Tr·cm^(-2)/(k Bq·m^(-3)·h)和7.3 Tr·cm^(-2)/(k Bq·m^(-3)·h)。建立的铝箔分辨法可有效用于222Rn和220Rn的分辨测量。 To measure Thoron concentration, the relationship was established between loss energy of α- ray e- mitted by 241 Am and thickness of aluminum foil which was also demonstrated by 6.00 and 7.69 MeV of α- ray emitted by Radon progenies 218Po and 214Po separately. The optimized resist thickness of aluminum foil is 46.60 μm,with which the calibration factors of Thoron and its progenies is 0.53 Tr cm-2/(kBq m-3 h) and 7. 3 Tr cm-2/( kBq m-3 . h) determined by the experiment of exposure in Thoron chamber and Thoron proge- ny chamber. The method established in this paper can discriminate between Radon and Thoron efficiently.
出处 《核电子学与探测技术》 CAS 北大核心 2016年第6期616-618,624,共4页 Nuclear Electronics & Detection Technology
关键词 铝箔 分辨法 钍射气 阻挡厚度 aluminum foil discriminating method Thoron resist thickness
  • 相关文献

参考文献4

二级参考文献38

  • 1肖德涛,赵桂芝.被动积分测^(220)Rn方法及其应用[J].南华大学学报(自然科学版),2004,18(4):7-13. 被引量:4
  • 2联合国原子辐射效应科学委员会.电离辐射源与效应(UNSCEAR2000向联合国大会提交的报告)[M].太原:山西科学技术出版社,2002.9.
  • 3张梦欣,孙连捷.安全科学技术百科全书[M].北京:中国劳动社会保障出版社,2003.
  • 4Urosevic V, Nikezic D, Vulovic S. A theoretical ap- proach to indoor radon and thoron distribution [ J ]. Journal of Environmental Radioactivity, 2008, 99 (12) : 1829 -1833.
  • 5ICRP. Lung cancer risk from radon and progeny and statement on radon, ICRP publication 115[R]. Sweden.. ICRP, 2010.
  • 6UNSCEAR. Annex E: Sources-to-effects assess ment for radon in homes and workplaces [R]. New York: UNSCEAR, 2009.
  • 7FLEISCHER R L. Theory of passive measure- ment of radon daughters and working levels by the nuclear track technique[J]. Health Physics, 1984, 47: 263-270.
  • 8NIKEZIC D, BAIXERAS C. Radon, radon progeny and equilibrium factor determination using LR-115 detector [J]. Radiation Measure- ments, 1996, 26: 203-213.
  • 9da SILVA A A R, YOSHIMURA E M. Verifi- cation of radioactive equilibrium to discriminate radon and progeny with LR-115 under thin film geometry[J].Radiation Measurements, 2005, 39.. 617-620.
  • 10ZHUO W H, IIDA T. Estimation of thoron progeny concentrations in dwellings with their deposition rate measurements[J].Journal of Health Physics, 2000, 35.. 365-370.

共引文献15

同被引文献4

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部