通过实例介绍了基于溶液除湿方式的温湿度独立控制空调系统在医院改造项目中的应用。重点说明了冷热源的选择,新风机组选型原则,末端干盘管供回水温度的确定,以及在设计过程中需要重点关注的问题,并指出了温湿度独立控制空调系统在医院改造项目中具有较好的经济性和适用性。
Introduce a design of liquid desiccant based temperature and humidity independent control air-conditioning system in a hospital. The new air volume index, the dry coil design for recycle water temperature and other attention-worthy tips of the system are introduced in detail. At the same time this paper gives a concluding that the temperature and humidity independent control air conditioning is quite economical and applicable in hospital.
作者
丁燕
Ding Yan(CCDI GROUP', Shanghai, 20043)
出处
《制冷与空调(四川)》
2016年第5期549-551,556,共4页
Refrigeration and Air Conditioning
关键词
溶液除湿新风机组
温湿度独立控制
医院空调
节能
THIC
Liquid desiccant dehumidification
Air conditioning system in hospital
energy saving