摘要
针对新疆某油田CNG卸气站压缩机在冬季运行时发生气缸进液的事件,通过"人机料法环-鱼骨图"的分析方法找出了压缩机气缸进液的根本原因,并提出针对性的改进措施,以提高卸气站综合管理水平,保证压缩机平稳运行,为安全生产提供保障。
Aiming at the event of the liquid entering the compressor's cylinder occurred in the CNG discharge gas station compressor in an oilfield of Xinjiang when operating in winter, through the analysis method of the 4M1E- Fishbone diagram to find out the root cause for the event, and the corresponding improvement measures put forward to improve the CNG discharge gas station comprehen- sive management level, and ensure the comoressor running smoothlv and safety, for providing guarantee for production.
作者
宋晓俊
SONG Xiao-jun(TARIM Oilfield Company KUCHE Project Department, CNPC, Korla 841000, China)
出处
《压缩机技术》
2016年第5期34-38,共5页
Compressor Technology
关键词
往复压缩机
气缸
人机料法环
鱼骨图
reciprocating compressor
cylinder
4M1E
Fishbone diagram