期刊文献+

调车模式下ATP报STM信息不合理问题分析

Analysis of Why ATP Reporting STM Information Unreasonable under Shunting Mode
下载PDF
导出
摘要 针对动车组由广珠动车所进广州南站时多次报ATP故障停车问题进行深入分析,发现是由于ATP车载设备和列控地面结合设备存在设计缺陷造成。针对该设计缺陷,探讨提出了3种解决方案建议。 As for several occurrences of train stopping caused by ATP failures when EMUs are pulling into Guangzhou South Railway Station from the Guangzhu depot,an in-depth analysis is made to find that the problem was caused due to design defects in ATP on-board equipment and ground equipment. To address those defects in design,three solutions are put forward.
出处 《铁道通信信号》 2016年第11期57-58,共2页 Railway Signalling & Communication
关键词 故障 列控地面设备 设计缺陷 Fault Ground train control equipment Defects in design