期刊文献+

蒸馏装置常顶换热器换热管泄漏原因分析

CAUSE ANALYSIS ON THE TUBE LEAKAGE OF ATMOSPHERIC DISTILLATION TOWER OVERHEAD HEAT EXCHANGER IN DISTILLATION UNIT
下载PDF
导出
摘要 对蒸馏装置常顶换热器频繁泄漏的原因进行分析,得出了换热管泄漏的主要原因是露点腐蚀和铵(胺)盐结晶沉积形成的垢下腐蚀共同作用的结果,其中塔顶注水量的不足加剧了腐蚀,这也是垢样中铁的腐蚀产物所占比重较大的原因。文章提出了降低铵(胺)盐结晶量;降低塔顶温度,加大蒸汽冷凝水注入量,使形成的铵(胺)盐及时溶解;对换热器换热管材质进行升级的三个针对性建议。 This paper analyzes the reasons for the frequent leakage of atmospheric distillation tower overhead heat exchanger.It is found out that the main reason for the tube leakage is the results of joint action from the dew point corrosion and under-deposit corrosion formed by ammonium(amine)salt crystallization & deposition,among which insufficient top water injection intensifies the corrosion.This is also the reason why iron corrosion products account for the larger portion of the scale samples.This paper puts forward three pertinent solutions to deal with the leakage problem covering reducing ammonium(amine)salt volume;reducing distillation tower top temperature and increasing the steam condensate injection rate so as to dissolve the formed ammonium(amine)salt in time;replacing and upgrading the material of the heat exchanger tube.
作者 符长军
出处 《石油化工设备技术》 CAS 2016年第5期61-63,6,共3页 Petrochemical Equipment Technology
关键词 常顶换热器 露点腐蚀 垢下腐蚀 泄漏 Atmospheric distillation tower overhead heat exchanger Dew point corrosion Under-deposit corrosion Leakage
  • 相关文献

参考文献1

二级参考文献8

  • 1NACE 34109. Crude Distillation Unit- Distillation Tower Over- head System Corrosion [ S ]. 2009.
  • 2Zhenhua Dan, Shunsuke Takigawa, Izumi Muto, et al. Applica- bility of constant dew point corrosion tests for evaluating atmos- pheric corrosion of aluminium alloys [ J ]. Corrosion Science, 2011,53 (5) :2006-2014.
  • 3Yange Yang,Tao Zhang,Yawei Shao,et al. Insitu study of dew point corrosion by electrochemical measurement [ J ]. Corrosion Science,2013,71 : 62-71.
  • 4Ulf K. A testmethod for dewpoint corrosion of stainless steels in dilute hydrochloric acid [ J ]. Corrosion Science, 2003,45 ( 3 ) : 485 -495.
  • 5J. M. Blanco, F. Pena. Increase in the boiler' s performance in terms of the acid dew point temperature : Environmental advan- tages of replacing fuels [ J ]. Applied Thermal Engineering, 2008,28(7) :777-784.
  • 6偶国富,曹晶,谢浩平.加氢裂化空冷管束流动传热的耦合模拟[J].炼油技术与工程,2010,40(11):42-45. 被引量:5
  • 7张基标,郝卫,赵之军,胡兴胜,殷国强.锅炉烟气低温腐蚀的理论研究和工程实践[J].动力工程学报,2011,31(10):730-733. 被引量:71
  • 8李淑娟.8Mt/a常减压蒸馏装置腐蚀与防护[J].石油化工腐蚀与防护,2011,28(5):27-30. 被引量:6

共引文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部