摘要
为解决修山水电站近几年出现的技术供水系统冷却效果差的问题,对技术供水系统的取水滤网、滤水器、空气冷却器等关键设备进行技术改造。从而使修山水电站技术供水系统冷却效果得到极大的提高,满足了机组正常安全运行,为夏季的丰水期机组高负荷运行提供了有力的保障。
To solve the bad cooling effect of technical water supply system in Xiushan Hydropower Station in recent years,technological transformation have been implemented on technical water supply system water filter,water filter,air cooler these key equipments,so that the cooling effect of technical water supply system can be greatly improved to meet the normal and safe operation of the unit,which providing a powerful guarantee for the summer of abundant water period unit high load operation.
出处
《广东水利水电》
2016年第1期52-55,共4页
Guangdong Water Resources and Hydropower
关键词
修山水电站
技术供水系统
拦污滤网
滤水器
hydropower station
technical water supply system
sewage filter
water filter