期刊文献+

四氟化铀中钍等二十三种杂质元素的测定 被引量:3

Determination of Thorium i.e 23 Trace Elements in UF_4
下载PDF
导出
摘要 本工作采用体积比1∶1浓硝酸和过氧化氢(φ=30%)加热溶解四氟化铀(UF4)后,再用浓硝酸或浓盐酸反复溶解蒸干,去除氟离子。在3mol/L硝酸介质中,采用15mm×105mm CL-TBP萃淋树脂柱分离铀中杂质,收集第6—15mL淋洗液,用等离子体发射光谱法(ICP-AES)进行测量。Al等22种元素回收率在97%~113%之间,除Al、Ca、Ba和Bi外其它元素相对标准偏差在5%以内(n=5)。在6mol/L盐酸介质中采用15mm×105mm CL-TBP萃淋树脂柱分离铀中Th,进行ICP-MS测量。Th回收率在91%~94%之间,相对标准偏差在5%以内(n=5),分析方法的检测下限为0.037μg/g(以UF4计)。 A method for determination of thorium i. e 23 trace elements in UF4 is established. In this work, UF4 was dissolved by HNO3 and φ=30% H202 with a volume ratio 1 : 1, then evaporated to dry repeatedly for the removal of F . By using a 415 mm× 105 mm CL-TBP column extraction chromatography, A1 i. e 22 trace elements were separated with uranium in 3 mol/L HNO3, the sixth to fifteenth mL eluent were collected for determination by ICP- AES. The recovery of these elements is between 97%-113%, and the relative standard deviation (st) is better than 50%(n= 5) unless A1, Ca, Ba and Bi. In 6 mol/L HC1, the uranium was separated by TBP levextred resin chromatography, and the thorium was determined by ICP-MS. The recovery of Th is between 91%-94%, and the sr is within 5% (n=5), and the detection limit of this separation method is 0. 037 μg/g UF4.
出处 《核化学与放射化学》 CAS CSCD 北大核心 2016年第5期296-302,共7页 Journal of Nuclear and Radiochemistry
关键词 四氟化铀 杂质 CL-TBP萃淋树脂 分析 UF4 thorium trace elements CL-TBP extraction resin analysis
  • 相关文献

参考文献6

二级参考文献21

  • 1王翠萍,董世哲,李琳,贺美英.ICP-AES法测定铀铌锆合金中的铌和锆[J].原子能科学技术,2003,37(z1):169-172. 被引量:10
  • 2关景素,原子能科学技术,1991年,25卷,6期,8页
  • 3关景素,分析化学,1986年,14卷,5期,372页
  • 4姬俊英,原子能科学技术,1985年,19卷,2期,233页
  • 5孟兰香,原子能科学技术,1983年,17卷,5期,592页
  • 6关景素,原子能科学技术,1980年,23卷,3期,40页
  • 7覃善章,理化检验通讯,1966年,2期,60页
  • 8关景素,1988年
  • 9潘复兴,分析化学,1987年,15卷,4期,322页
  • 10关景素,原子能科学技术,1985年,2期,230页

共引文献20

同被引文献16

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部