摘要 以原子荧光法测定油田废水中砷含量为实例,建立数学模型,分析和识别在分析过程中的不确定度来源,对测量中不确定度的各个分量进行了分步计算及合成,计算出测定结果的扩展不确定度0.74μg/L。通过计算和分析,结果表明,标准工作曲线拟合和方法回收率是原子荧光法测定油田废水中砷含量的不确定度的主要因素。 By using atomic fluorescence method to determine arsenic content in wastewater of oil field, established a mathemat- ical model, analysed and identified the sources of uncertainty in the process of analysis, calculated and synthesized the meas- urement uncertainty of the various components by steps, then calculated the expanded uncertainty of the determination results was 0.74 μg/L. The calculation and analysis results showed that the standard working curve fitting and method recovery rate is the main factor influenced the uncertainty in determination of arsenic in waste water by atomic fluorescence spectrometry.
作者 朱维
出处 《干旱环境监测》 2016年第4期185-190,共6页 Arid Environmental Monitoring
关键词 原子荧光法 不确定度 atomic fluorescence spectrometry arsenic uncertainty
  • 相关文献

参考文献1

二级参考文献5

  • 1JJFl059-1999《测量不确定度评定与表示》.中国质量技术监督局.北京:计量出版社,2000.
  • 2王克勤.不确定度在检测实验室的应用《安全与电磁兼容》.主办单位:中国电子技术标准化研究所,2001.4.
  • 3杨世元,吴国平等.电器质量检测不确定度.北京:中国标准出版社,2002.
  • 4赵家瑞.关于电器产品检测不确定度相关问题的探讨.家电科技,主办单位:中国家用电器研究所,2004.7.
  • 5李慎安等.测量误差及数据处理技术规范解说.北京:中国计量出版社,1996.