期刊文献+

9S管理在流动采血车血液采集质量管理中的应用探讨 被引量:8

Study on Application of 9S Management in the Blood Collection Quality Management by the Mobile Blood Collecting Vehicles
下载PDF
导出
摘要 目的分析9S管理在流动采血车血液采集质量管理中的应用。方法选择该站2个流动采血车为研究对象,实施9S管理,分析9S管理实施前后的物品摆放标准化、物品取放流程合理性、物品材料过期发生率、器械设备维修率、献血者满意度、护士对科室管理满意度等指标。结果伴随着9S开展时间,流动采血车的各项指标均有明显的改善,各项指标实施1年后与实施前差异有统计学意义(P<0.05)。结论 9S管理在流动采血车血液采集质量管理中的应用效果显著,能够有效提升采集血中各项工作质量,值得推广。 Objective To analyze the application of 9S management in the blood collection quality management by the mobile blood collecting vehicles. Methods 2 mobile blood collecting vehicles in our station were selected and were given the9 S management, and the indexes including the article display standardization, article pick-and-place process rationality, incidence rate of overdue article materials, maintenance rate of instruments and equipment, satisfactory degree of blood donors and satisfactory degree of nurses to department management before and after the implementation of 9S management were analyzed. Results The development of 9S obviously improved various indexes of mobile blood collecting vehicles, and the differences in various indexes after 1-year implementation and before implementation were obvious with statistical significance, P〈0.05. Conclusion The application effect of 9S management in the blood collection quality management by the mobile blood collecting vehicles is obvious, which can effectively improve various working qualities in the blood collection, and it is worth promotion.
作者 李海平
出处 《中国卫生产业》 2016年第33期87-89,共3页 China Health Industry
关键词 9S管理 流动采血车 血液采集质量管理 应用效果 9S management Mobile blood collecting vehicles Blood collection quality management Application effect
  • 相关文献

参考文献9

二级参考文献30

  • 1高美叶 任红霞 张艳梅.流动采血车采集血液的质量管理.中国实用医药,2005,6.
  • 2李玉芹.浅谈采血车血液采集质量管理.中国康复,2007,11.
  • 3秦丽.浅谈采血车血液采集质量管理的几个环节[M].北京:人民卫生出版社,1993.
  • 4陈仲武.采血车质量管理的环节.中国康复医学杂志,2006,8.
  • 5中华人民共和国卫生部.中国国家标准化管理委员会.全血及成分血质量要求.2012-01-04.
  • 6Notari EP 4th, Orton SL, Cable RG, et al. Seroprevalenee of known and putative hepatitis markers in United States blood do- nors with ALT levels at least 120 IU per L [J]. Transfusion, 2001,41(6) :751-755.
  • 7Brinkmann T,Dreier J, Diekmann J, et al. Alanine aminotrans- ferase cut-off values for blood donor screening using the new in- ternational federation of clinical chemistry reference method at 37"C [J]. Vox Sang, 2003,85(3) : 159-164.
  • 8侯广安.温度对采血车空气消毒效果的影响[J].中国误诊学杂志,2009,9(21):5128-5129. 被引量:6
  • 9吴建文.如何加强流动采血车采集血液的质量管理[J].中国民族民间医药,2009,18(19):31-31. 被引量:3
  • 10范晓芹,黄桂圆,董奕裕.持续质量改进在病区血标本采集中的应用[J].护理学报,2010,17(8):29-30. 被引量:29

共引文献29

同被引文献40

引证文献8

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部