期刊文献+

去金属伪影序列syngo WARP在磁共振成像中的应用 被引量:7

Clinical research of syngo WARP in the magnetic resonance imaging
下载PDF
导出
摘要 目的:探讨一种去金属伪影序列(syngo WARP)扫描在金属植入物患者骨肌磁共振成像中的应用价值。方法:选取35例接受过金属植入物手术的患者,分别行常规序列及WARP序列扫描,所得图像质量评分用中位数(P25,P75)表示。使用Wilcoxon符号秩次检验比较两种序列之间的评分有无统计学差异,运用Kappa检验评价两名评分医生评价的一致性。结果:采用WARP序列进行扫描的图像质量评分为3(2,3)明显高于常规序列的2(1,2),差异有统计学意义(Z=-5.097,P<0.001)。两名评分医生一致性检验显示,使用WARP序列的Kappa值为0.615(P<0.001),高于常规序列(Kappa值为0.126,P=0.302)。结论:使用WARP扫描技术可以明显改善图像质量,丰富术后诊断信息。 Objective:To investigate the clinical value of syngo WARP sequence in patients with musculoskeletal metallic prosthesis.Methods:Thirty-five patients with metallic prosthesis were enrolled,and received conventional sequences and sequences with syngo WARP,the quality score of image was indicated by median(P25,P75).Wilcoxon signed rank test was performed to compare the differences of image quality score between two sequences,and Kappa test was used to evaluate the consistency of the results by two doctors.Results:The image quality score of sequences with syngo WARP was scored by3(2,3),which was significantly higher than conventional sequence 2(1,2)(Z=-5.097,P〈0.001).The consistency of scores by two doctors showed that the Kappa value of sequences with syngo WARP was 0.615(P〈0.001),which was higher than conventional MR sequences(kappa=0.126,P=0.302).Conclusions:Syngo WARP technique could effectively improve the image quality,and provide postoperative diagnostic information.
出处 《中国临床医学》 2016年第5期644-647,共4页 Chinese Journal of Clinical Medicine
关键词 金属伪影 图像质量 磁共振成像 metal artifacts image quality magnetic resonance imaging
  • 相关文献

参考文献2

二级参考文献22

  • 1Sutter R, Ulbrich E J, Jellus V, et al. Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging [J]. Radiology, 2012, 265:204-214.
  • 2Darnell JC, Saltiel AR. Coenzyme A-dependent, ATP- independent acylation of 2-acy! lysophosphatidylinositol in rat liver microsomes[ J]. Biochim Biophys Acta, 1991, 1084:292-299.
  • 3Knight SR, Aujla R, Biswas SP. Total Hip Arthroplasty-over 100 years of operative history[ J]. Orthop Rev ( Pavia), 2011,3 : e16.
  • 4Learmonth ID, Young C, Rorabeck C. The operation of the century: total hip replacement [ J ]. Lancet, 2007, 370: 1508-1519.
  • 5Goodman S. Wear particulate and osteolysis [ J ] . Orthop Clin North Am ,2005,36:41-48.
  • 6Gallo J, Goodman SB, Konttinen YT, et al. Osteolysis around total knee arthroplasty : a review of pathogenetic mechanisms [ J ].Acta Biomater, 2013,9 : 8046-8058.
  • 7Anderson H, Toms AP, Cabir JG, et al. Grading the severity of soft tissue changes associated with metal-on-metal hip replacements: reliability of an MR grading system [ J ]. Skeletal Radiol, 2011,40:303-307.
  • 8Campbell P, Ebramzadeh E, Nelson S, et al. Histological features of pseudotumor-like tissues from metal-on-metal hips [ J ]. Clin Orthop Relat Res, 2010,468 : 2321-2327.
  • 9Counsell A, Heasley R, Arumilli B, et al. A groin mass caused by metal particle debris after hip resurfacing [ J ]. Aeta Orthop Belg, 2008,74:870-874.
  • 10Cahir JG, Toms AP, Marshall TJ, et al. CT and MRI of hip arthroplasty[ J]. Clin Radiol, 2007,62 : 1163-1171.