双调制多波长旋光法检测人工前房内葡萄糖的浓度 被引量:4

Dual-Modulation Multi-Wavelength Polarimetry for Monitoring Glucose Concentration in Anterior Chamber of Eye Phantoms
原文传递
导出
摘要 光学旋光法是一种无创血糖检测技术,通过测量眼前房水内葡萄糖浓度来确定体内血糖浓度水平。人眼运动引起的实时变化的双折射是实现旋光法无创血糖测量的主要限制因素之一。设计了实时、闭环、双调制多波长偏振系统来测量人工前房内的葡萄糖浓度,人工前房由离体角膜固定在人工眼房上构成。采用眼耦合装置使光直线穿过眼前房从而避免了空气与角膜之间折射率不匹配引起的光线弯曲。存在运动引起的双折射时,采用双波长旋光系统测量眼模型内的葡萄糖浓度,两次预测葡萄糖浓度的标准差分别为18.9mg/dL和15.2mg/dL,表明该系统具有降低活体角膜实变双折射的潜力,有利于实现与血糖浓度相关的眼前房水内葡萄糖浓度的精确测量。 Optical polarimetry is a noninvasive glucose monitoring technique which can be potentially used to ascertain blood glucose levels through measuring the aqueous humor glucose levels in the anterior chamber of the eye.One major limitation of the polarimetric approach as a means to noninvasively measure glucose levels is timevariant corneal birefringence caused by motion artifact.We design a real-time,closed-loop,dual-modulation,multiwavelength polarimetric system for glucose measurement by using an isolated human cornea ex vivo clamped on an artificial anterior chamber.Eye coupling devices are utilized to prevent bending of the light through the anterior chamber due to index mismatch between air and aqueous humor barrier.The polarimetric setup for glucose measurement ex vivo is presented and the system predicts the glucose concentration with standard error of18.9mg/dL and 15.2 mg/dL in the presence of birefringence with motion at two runs.The results indicate that polarimetry can effectively be used to minimize the effect of corneal birefringence in vivo,and helps to accurately measure glucose concentration in the aqueous humor of the eye that is correlated with blood glucose levels.
出处 《光学学报》 EI CAS CSCD 北大核心 2016年第11期211-217,共7页 Acta Optica Sinica
关键词 医用光学 双调制 无创检测 光学旋光法 血糖检测 medical optics dual modulation noninvasive measurement optical polarimetry blood glucose monitoring
  • 相关文献

参考文献6

二级参考文献142

  • 1张洪艳,张来明,陈月,刘少明,孙颖,唐玉国.近红外漫反射光谱在人体血糖无创检测中的应用[J].激光与红外,2005,35(2):96-99. 被引量:5
  • 2O S Khalil. Spectroscopic and clinical aspects of noninvasive glucose measurements [J]- Clinical Chemistry, 1999, 45(2): 165--177.
  • 3K Maruo, M Tsurugi, M Tamura, et al.. In vivo noninvasive measurement of blood glucose by near-infrared diffuse-reflectance spectroscopy [J]. Applied Spectroscopy, 2003, 57(10): 1236--1244.
  • 4G W Hopkins, G R Mauze. In-vivo NIR diffuse-reflectance tissue spectroscopy of human subjects [C]. SPIE, 1999, 3597: 632-- 641.
  • 5J P Bantle, W Thomas. Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid [J]. Journal of Laboratory and Clinical Medicine, 1997, 130(4):436--441.
  • 6E Kulcu, J A Tamada, G Reach, a al.. Physiological differences between interstitial glucose and blood glucose measured in human subjects [J]. Diabetes Care, 2003, 26(8): 2405--2409.
  • 7K Rebrin, Jr N F Sheppard, G M Steil. Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset [J]. J Diabetes Sci Technol, 2010, 4(5): 1087--1098.
  • 8T Maeda, N Arakawa, M Takahashi, et al.. Monte Carlo simulation of spectral reflectance using a multilayered skin tissue model[J]. Opt Rev, 2010, 17(3).- 223--229.
  • 9V V Tuchin, S R Utz, I V Yaroslavsky. Tissue optics, light distribution, and spectroscopy [J]. Opt Eng, 1994, 33(10): 3178--3188.
  • 10O Kim, J McMurdy, C Lines, et al.. Reflectance spectrometry of normal and bruised human skins: experiments and modeling [J]- Physiol Meas, 2012, 33(2): 159.

共引文献79

同被引文献36

引证文献4

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部