目的:考察不同企业生产的五氟利多片的含量均匀度。方法:采用HPLC法,Diamonsil^(TM)C_(18)(4.6 mm×250 mm,5μm)色谱柱,流动相为甲醇-0.2%三乙胺溶液(用磷酸调节p H值至2.5)(70∶30),检测波长219 nm。结果:不同企业生产的五氟利多片的含量均匀度检查结果差异较大。结论:五氟利多片标准中增加含量均匀度检查项,可以加强对生产企业的监督管理,保证药品质量。
Objective: To investigate the content uniformity of Penfluridol Tablets from different manufacturers. Methods : HPLC method was performed on a DiamonsilTMC19 column(4. 6 mm ×250 mm, 5 μm), the mobile phase was consisted of methanol -0. 2% triethylamine solution (adjusted pH to 5. 5 with phosphoric acid) (70: 30) and the detection wavelength was set at 219 nm. Results:There were significant differences in content uniformity of Penfluridol Tablets from different enterprises. Conclusion: Adding content uniformity item to the official standard of Penfluridol Tablets could reinforce the management of pharmaceutical enterprises and guarantee the quality of the drugs.
出处
《中国药品标准》
CAS
2016年第5期329-330,共2页
Drug Standards of China
关键词
五氟利多片
含量均匀度
Penfluridol Tablets
content uniformity