期刊文献+

基于AOTF的多光谱红外成像系统MRTD测试技术研究 被引量:2

MRTD in multi-spectral infrared imaging system based on AOTF
下载PDF
导出
摘要 为了实现红外多光谱成像系统光谱维MRTD测试,获取更多的目标背景信息,提出基于声光可调谐滤波器(AOTF)的多光谱成像系统静态性能测试平台的设计。在(3~5)μm波段范围内,采用设计搭建的静态性能测试平台完成了红外带内波段的细分,并在各个细分波段上分别对空间频率2.546lp/mm、1.273lp/mm、0.849lp/mm和0.632lp/mm的标准靶进行了MRTD测试。实验结果表明,得到的光谱维MRTD测试结果与理论结果一致,验证了测试平台的可靠性和测试方法的可行性。 In order to achieve the spectral minimum resolvable temperature difference(MRTD)testing of infrared multi-spectral imaging and obtain more information of target and background,an acousto-optic tunable filter(AOTF)-based multi-spectral static performance testing platform was designed and developed.At 3μm^5μm waveband,through adopting the designed optical testing platform,the subdivision of band was carried out in middle-wave infrared region,and the MRTD tests were finished in targets with different spatial frequencies of 2.546lp/mm,1.273lp/mm,0.849lp/mm and 0.632lp/mm,respectively.The experimental result shows that,the test results of spectral MRTD correspond with the theoretic analysis,verifying the reliability of the optical testing platform and the feasibility of the testing method.
出处 《应用光学》 CAS CSCD 北大核心 2016年第6期932-937,共6页 Journal of Applied Optics
基金 部级青年科技基金项目(51302060111)
关键词 多光谱成像 红外多光谱 声光可调谐滤波器(AOTTF) 性能表征 MRTD multi-spectral imaging infrared multi-spectral acousto-optic tunable filter(AOTF) performance characterization MRTD
  • 相关文献

参考文献7

二级参考文献38

  • 1李庆,刘上乾,赖睿,王炳健.一种基于场景的红外焦平面阵列非均匀性校正算法[J].光子学报,2006,35(5):720-723. 被引量:24
  • 2吴新社,蔡毅.红外凝视成像系统中的光学微扫描技术[J].红外与毫米波学报,2007,26(1):10-14. 被引量:28
  • 3[3][俄]S.A.瓦金等著,吴汉平等译.电子战基本原理[M].北京:电子工业出版社,2004,5.
  • 4[4]周刚等.舰艇电子战系统作战使用[M].北京:海潮出版社,2007,2.
  • 5KOSTRZEWA J, LONG J, GRAFF J H, et al. TOD versus MRT when evaluating thermal imagers that exhibit dynamic performance [ J ]. Proc. of SPIE, 2003, 5076 : 220 - 232.
  • 6IRWIN A, GAULITNEY P, WHITE S. Discussion of IR Testing Using IRWindows^TM 2001 [ M ]. Santa Barbara: Santa Barbara Infrared, Inc FLIR Systems, Inc, 2002.
  • 7BIJL P, SCHU33E K, HOGERVORST M A. Applicability of TOD, MTDP, MRT and DMRT for dynamic image enhancement techniques [ C ]//Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XVII. Washington, CA. Proc. of SPIE, 2006, 6207. 1 - 12.
  • 8WITFENSTEIN W. Minimum temperature difference perceived--a new approach to assess undersampled thermal imagers [ J]. Optical Engineering, 1999, 38 (5) : 773 - 781.
  • 9WEBB C, HALFORD C. Dynamic minimum resolvable temperature testing for staring array imagers[ J]. Optical Engineering, 1999, 38 (5) : 845 - 851.