期刊文献+

古塔整体平移后的抗震性能分析与隔震改造 被引量:1

Analysis of Seismic Characteristics of Ancient Pagoda after Monolithic Translation and Isolation Retrofitting
下载PDF
导出
摘要 利用数值模拟方法研究龙溪塔整体平移后的动力特性及其抗震性能。考虑塔檐、塔刹以及开洞等构造,建立平移后古塔的三维实体有限元模型,进行了模态分析和时程分析,通过输入不同地震波,计算出结构在多遇地震与罕遇地震情况下塔体的位移反应、层间位移角以及应力等。结果表明:在不同地震波作用下古塔一层墙体和二层墙体与塔檐连接处应力较大,一层角部最大应力值已超过材料极限强度;塔刹的位移反应与塔身相比较大;层间位移角随层高增加而增大,在多遇地震下塔刹处层间位移角远小于层间位移角限值,古塔主体结构处于弹性状态,不发生破坏;在罕遇地震作用下,除一层以外各层的层间位移角均超过限值,二三层结构有轻微破坏,四至七层结构出现中等破坏,塔刹严重破坏甚至倒塌。提出龙溪塔整体平移后的隔震改造建议,对比分析隔震前后古塔的抗震性能,结果表明在平移后的建筑物下设置隔震支座减震效果明显。 The dynamic characteristics and seismic behaviors after monolithic translation of Longxi Pagoda is studied by numerical simulation method. Its finite element model of three entities is built considering constitutions such as pagoda eaves,pagoda finial,openings and so on. A model analysis and a transient analysis are then conducted. The displacement of the pagoda and the inter-story drift angle of the floors under frequent seismic actions and infrequent seismic actions are calculated by inputting different seismic waves. It is shown through the results that the walls of the bottom layer and the joint of the second layer and pagoda eaves have larger stress,and the maximum stress value of the bottom layer has already exceeded the ultimate strength of materials. The displacements of pagoda finial are larger than the body of pagoda. The inter-story drift angle increases with the increasing height of the pagoda. The inter-story drift angle of pagoda finial is far less than inter-story drift angle limitation under frequent seismic actions so that the main structure is in the elastic state and will not be damaged. Under infrequent seismic actions,the inter-story drift angle of each layer exceeds the limitation except the first layer,the second and third layers of structure damage slightly and the forth layer to seventh layer are in moderate damage,the pagoda finial is seriously damaged or even collapses. The isolation retrofitting proposals for protecting Longxi Pagoda after monolithic translation and the contrast analysis of the seismic performance of the ancient pagoda before and after isolation retrofitting are proposed. The results indicate that the seismic response of structure which is placed the isolation bearings after the monolithic translation is reduced sharply.
出处 《工程抗震与加固改造》 北大核心 2016年第5期136-143,150,共9页 Earthquake Resistant Engineering and Retrofitting
关键词 古塔 抗震性能 整体平移 隔震 ancient pagoda seismic behavior monolithic translation isolation
  • 相关文献

参考文献6

二级参考文献26

  • 1魏陆顺,周福霖,刘文光.广州大学城应用组合基础隔震技术[J].建设科技,2005(2):30-31. 被引量:9
  • 2GE Xin-hui YU Guang-yun.Influence of Underground Mining on Ground Surface and Railway Bridge Under Thick Alluvium[J].Journal of China University of Mining and Technology,2006,16(1):97-100. 被引量:8
  • 3杜健民,袁迎曙,向伟.框架柱托换体系抗冲剪承载力预计模型研究[J].中国矿业大学学报,2007,36(1):60-64. 被引量:26
  • 4中国建筑科学研究院工程抗震研究所八室.西安市大雁塔等六座古建筑物动态试验报告[R].1988,5
  • 5MELKUMIAN M G. The use high damping rubber Isolators to upgrade earthquake resistance of existing buildings in armenia[J].International Post-SMIRT Conference on Isolation Energy Dissipation and Control of Vibration of Structures, 1997:861-867.
  • 6MELLY J. M. Progress of applications and development in base Isolation for civil and industrial structures on the united states [J]. International Post- SMIRT Control of Seismic Vibrations of Structures, 1999:730-734.
  • 7MOKHA A C, CONSTANTIONOU A M, REINBORN V Z. Experimental study of friction pendulum system isolation system[J]. Journal of Structural Engineering, ASCE, 1991,117(4) : 1201-1217.
  • 8PIRROTTA A, IBRAHIM R A. Experimental investigation of friction-base isolation[J]. Probabilistic Engineering Mechanics, 1997,12(3) : 125-136.
  • 9JANGID R S, DATTA T K. The stochastic response of asymmetric base isolated buildings[J].Journal of Sound and Vibration, 1995,179(3) : 463- 473.
  • 10STEFANO S, GLORIA T. Non-linear dynamic design procedure of FV spring-dampers for base isolation-frame building applications [J]. Engineering Structures, 2001,23(12):1568-1576.

共引文献36