摘要 广东电网潮流特性复杂,重大停电检修密集交错,导致网架结构薄弱,系统运行风险加大。为了提高电网故障后的快速恢复能力,对广东电网内单轴式与双轴式燃气–蒸汽联合循环机组特性进行了分析,从而得到其正常运行、调峰与黑启动的经验总结。结合快速切负荷(fast cut back,FCB)技术原理和燃气–蒸汽联合循环机组运行特性进行了建模,提出了考虑负荷爬坡速率与快速恢复时间的优化模型。通过实例数据,验证了该模型的应用对电网故障后快速恢复的有效性、实用性。 Power flow characteristics of Guangdong power grid are complex and overhaul for major power outages is intensive, which may cause grid structure weak and system running risks increase. In order to improve fast recovery ability of the power grid after failure, this paper analyzes characteristics of single shaft gas-steam combined cycle turbine and double shaft gas-steam combined cycle turbine of Guangdong power grid, and obtains experiences of normal operation, peak load and black start. Based on modeling according to fast cut back (FCB) technology principle and operational characteristics of gassteam combined cycle turbine, it proposes an optimized model considering load climbing rate and fast recovery time. On the basis of example data, it proves validity and practicability of this model in realizing fast recovery of the power grid after failure.
作者 董超 曾凯文 陈钢 呼士召 陈启鑫 DONG Chao ZENG Kaiwen CHEN Gang HU Shizhao CHEN Qixin(Guangdong Power Grid Power Dispatching Control Center, Guangzhou, Guangdong 510600, China State Key Laboratory of Control and Simulation of Power System and Generation Equipment, Tsinghua University, Beijing 100084, China)
出处 《广东电力》 2016年第11期81-85,共5页 Guangdong Electric Power
基金 国家自然科学基金项目(51477121) 霍英东教育基金会青年教师基金(151057) 广东电网有限责任公司科技项目(036000KK52150007)
关键词 燃气–蒸汽联合循环 调峰特性 黑启动能力 快速切负荷技术 故障恢复 gas-steam combined cycle peak load regulation characteristic black start ability fast cut back fault recovery
  • 相关文献

参考文献7

二级参考文献55

共引文献77

同被引文献35

引证文献4

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部