期刊文献+

主成分分析方法在空间干涉仪图像处理中的应用 被引量:1

Principal component analysis for interferometer image processing in SSRF
下载PDF
导出
摘要 在干涉仪图像数据处理过程中,目前采用的多行平均图像处理算法会引入较大随机误差,且当CCD相机与狭缝之间存在小转角时,会引入较大系统误差。本文主要探究利用主成分分析(PCA)算法处理空间干涉仪图像的可行性与优势。利用MATLAB模拟空间干涉仪图像,并加入随机噪声和图像旋转,利用PCA方法和多行平均算法处理数据,比较两种算法的得到的结果误差大小。并设计CCD相机小转角实验和干涉图像弱信号实验,评估PCA算法在数据处理过程中纠正CCD相机小转角和重建弱信号图像中的效果。理论和实验均证明,PCA算法较目前多行平均算法,能更有效地降低噪声,分析弱信号图像及纠正CCD相机小转角,消除其带来的系统误差。 The interferometer system for transverse beam size measurement was one of the important parts of storage ring diagnostics in Shanghai Synchrotron Radiation Facility (SSRF). The average of multiple lines and curve fitting method was adopted for raw image data processing now, but there were big random errors and system errors when the CCD is not aligned with the double slits. The article discusses the feasibility and the advantages about using principal component analysis(PCA) method to process the raw image data from the interferometer system. Using MATLAB simulation and two experiments with random noise and rotated CCD, comparing the results errors between PCA raw image data processing and normal average of.multiple lines method, it is concluded that the noise could be reduced and the small angle between CCD and double slits could be found out and corrected using PCA methods.
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2016年第12期128-135,共8页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(11375255 11075198)
关键词 主成分分析 空间干涉仪 图像处理 上海光源 principal component analysis interferometer image processing SSRF
  • 相关文献

参考文献3

二级参考文献24

  • 1仲伟波,宁书年,金声震,林捷.遥感成像噪声分析及基于PCNN的滤除方法[J].煤炭学报,2004,29(4):418-421. 被引量:8
  • 2张兢,路彦和,刘群英.改进的嵌入小波算法在遥感图像压缩中的应用[J].微计算机信息,2006(03Z):79-81. 被引量:1
  • 3Ferianis M. Optical techniques in beam diagnostics[C]//Proc of European Particle Accelerator Conference. 1998:159-163.
  • 4Andersson A, Chubar O. Beam profile measurements with visible synchrotron light on MAX Ⅱ[C]. Proc of European Particle Accelerator Conference. 1996:1689-1691.
  • 5Nakamura N, Sakai H, Iida K, et al. Electron beam size measurement with a beam profile monitor using Frcsncl zone plates[C]// Proc of Particle Accelerator Conference. 2003:530-532.
  • 6Thomas C, Rehm G. Pinhole camera resolution and emittance measurement[C]//Proc of European Particle Accelerator Conference, 2008:1254-1256.
  • 7Tordenx M, Cassinari L, Chubar O, et al. Ultimate resolution of Soleil X ray pinhole camera[C]//Proc of Diagnostics and Instrumentation for Particle Accelerator Conference. 2007 : 180-182.
  • 8Yamamoto Y, Sakaib I, Mitsuhashi T, et al. Interferometric measurement of the beam size in the compact storage ring[J]. Nuclear Instru- ments and Methods in Physics Research A, 2001, 467 468(2) :921-924.
  • 9Naito T, Mitsuhashi T. Very small beam size measurement by reflective SR interferometer at KEK ATF[C]//Proc of European Particle Ac- celerator Conference. 2006 :1142-1144.
  • 10Leng Yongbin, Ye Kairong, Zhou Weimin, et al. SSRF beam diagnostics system commissioning[C]//Proc of Diagnostics and Instrumenta tion for Particle Accelerator Conference. 2009:24-26.

共引文献12

同被引文献14

引证文献1

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部